I Set mode items

D D Scan mode
The transceiver has 2 scan modes: Normal scan and Priority
scan. Normal scan searches all tag channels in the selected
channel group. Priority scan searches all tag channels in se-
quence while monitoring Channel 16.
Set Mode
Scan Mode
Normal scan (default)
D D Scan resume timer
The scan resume timer can be selected as a pause (OFF) or
timer scan (ON). When OFF is selected, the scan pauses
until the signal disappears. When ON is selected, the scan
pauses 5 sec. and resumes even if a signal has been re-
ceived on any other channel than Channel 16.
Set Mode
Scan Timer
Scan timer OFF (default)
D D Weather alert
A NOAA broadcast station transmits a Weather alert tone be-
fore important weather information. When the Weather alert
function is turned ON, the transceiver detects the alert tone,
then blinks the "WX ALT" indicator and sounds beep tones
until the transceiver is operated. The previously selected
(used) weather channel is checked any time during standby
or while scanning.
• "WX ALT" appears instead of "WEATHER" indication when the
function is set ON.
Priority scan
D D Dual/Tri-watch
This item sets the
watch or Tri-watch.
Scan timer ON
Set Mode
WX Alert
Weather alert OFF (default)
[
[
CH/WX
]
]
CH/WX
(
(
DW
Set Mode
DUAL/TRI
Dualwatch (default)