E
2-2
lEctrIcal
REFRIGERATION
(Self Contained Models)
Each self contained model is equipped
with its own condensing unit and control
panel located beneath the display area. The
correct type of refrigerant will be stamped
on each merchandiser's serial plate. The
merchandiser refrigeration piping is leak
tested. The unit is charged with refrigerant,
and shipped from the factory with all service
valves open.
Refrigeration lines are under pressure.
Refrigerant must be recovered before
attempting any connection or repair.
When brazing pipes, be sure to use the
insulation blanket shipped with the
merchandiser to prevent damage to the
metal merchandiser bottom.
P/N 2402646_H
/ r
EfrIgEratIon
U.S. & Canada 1-800-922-1919 • Mexico 01 800-890-2900 • www.hussmann.com
WATER OUTLET AND WATER SEAL
The condensate water outlet is located at the
front corners of the evaporator coil area. The
outlet has a factory installed, external water
seal.
For self contained models, this water seal
drains into the condensate evaporator pan
located beneath the merchandiser.
NOTE: All lower base panels must be in place
when the refrigerator is operating. If not,
airflow from the condenser will be directed
over the evaporator pan and defrost water in
the pan may overflow.
Product will be degraded and may spoil if
allowed to sit in a non-refrigerated area.