Parameter settings for a motor with encoder
Combination with the vector control dedicated motor
When using the inverter with a vector control dedicated motor, refer to the table below.
• Combination with the SF-V5RU and SF-THY (ND rating)
Voltage
Rated speed
Base frequency
Maximum speed
Motor capacity
1.5 kW
2.2 kW
3.7 kW
5.5 kW
7.5 kW
11 kW
15 kW
18.5 kW
22 kW
30 kW
37 kW
45 kW
55 kW
75 kW
90 kW
110 kW
The maximum speed is 2400 r/min.
80% output in the high-speed range. (The output is reduced when the speed is 2400 r/min or faster.)
NOTE
• The SF-V5RU1 (speed ratio 1:1), SF-V5RU3 (speed ratio 1:3), and SF-V5RU4 (speed ratio 1:4) will be manufactured per
order.
62
INSTALLATION AND WIRING
400 V class
1500 r/min
50 Hz
3000 r/min
Motor frame
Motor model
number
90L
SF-V5RUH1K
100L
SF-V5RUH2K
112M
SF-V5RUH3K
132S
SF-V5RUH5K
132M
SF-V5RUH7K
160M
SF-V5RUH11K
160L
SF-V5RUH15K
180M
SF-V5RUH18K
180M
SF-V5RUH22K
200L
SF-V5RUH30K
200L
SF-V5RUH37K
200L
SF-V5RUH45K
225S
SF-V5RUH55K
250MD
SF-THY
250MD
SF-THY
280MD
SF-THY
Inverter model
FR-A846-[]
00083(2.2K)
00083(2.2K)
00126(3.7K)
00250(7.5K)
00310(11K)
00380(15K)
00470(18.5K)
00620(22K)
00770(30K)
00930(37K)
01160(45K)
01800(55K)
02160(75K)
02600(90K)
03250(110K)
03610(132K)