Installation of the inverter
2.3.2
Amount of heat generated by the inverter
Installing the heat sink inside the enclosure
When the heat sink is installed inside the enclosure, the amount of heat generated by the inverter unit is shown in the
following tables.
Amount of heat generated (W)
Inverter
FR-A846-[]
00023(0.4K)
50
00038(0.75K)
70
00052(1.5K)
80
00083(2.2K)
120
00126(3.7K)
160
00170(5.5K)
230
00250(7.5K)
325
00310(11K)
370
00380(15K)
440
00470(18.5K)
530
00620(22K)
700
00770(30K)
840
00930(37K)
1060
01160(45K)
1260
01800(55K)
1750
02160(75K)
2210
02600(90K)
2700
03250(110K)
2900
03610(132K)
3700
NOTE
• The amount of heat generated shown assumes that the output current is the inverter rated current, and the carrier frequency
is 2 kHz.