Adjust The Air Shutter (Front Burner) - Vermont Castings VC41LDVINTSC Installation And Operating Instructions Manual

Clean face direct vent fireplace insert
Table of Contents

Advertisement

VC41LDVI/VC41CDVI Gas Fireplace Insert
ADjuST The AIR ShuTTeR (FRONT
BuRNeR) VC41LDVI ONLy
The venturi of the front burner is equipped with an air
shutter. The opening of the venturi has been set at 1/4" for
Natural Gas and fully open for Propane installation at sea
level. The burner on Natural Gas models may be adjusted
for high altitude as follows:
1. Remove top and bottom brackets holding brick sides in
place by removing the screws. Carefully remove side
and rear brick panels.
2. Remove log support bracket by removing two (2) screws
in rear and one (1) screw on each side wall.
Figure 32 -
Push Adjustment Lip Up to
Open Air Shutter
Figure 33 -
Pull Adjustment Lip to Close Air Shutter
28
AIR ShuTTeR ADjuSTMeNT (NATuRAL GAS ONLy)
FP1940
air shutter part open
FP1941
air shutter fully open
3. Remove four (4) screws holding burner in place and
slide burner to the left and up and out of unit, allowing
access to venturi air shutter.
4. Adjust air shutter:
To increase air mixture, open the shutter more. This
will reduce soot formation. Figure 32
To decrease air mixture, close the shutter. Flames
will be more yellow. Figure 33
5. After adjusting air shutter, replace in reverse order.
Air Shutter
FP1940
Air Shutter
FP1941