(Vc41Ldvi Only) Adjust The Air Shutter (Rear Burner) - Vermont Castings VC41LDVINTSC Installation And Operating Instructions Manual

Clean face direct vent fireplace insert
Table of Contents

Advertisement

AIR ShuTTeR ADjuSTMeNT (NATuRAL GAS ONLy)
ADjuST The AIR ShuTTeR (ReAR
BuRNeR) VC41LDVI ONLy
This unit is equipped with a rear burner manual slide
adjustable air shutter for natural gas. Locate the slide
adjustment lever on the front lower left portion of the log
support bracket, just below the horizontal grate bar. The
slide adjustable air shutter has a range of 1". Figure 34
To increase air mixture, open the slide adjustment by
gently pulling on the lever. When lever stops it has
reached its maximum adjustment. This will reduce soot
formation.
To decrease air mixture, close the slide adjustment by
gently pushing on the lever. When lever stops, it has
reached its minimum adjustment. Flames will be more
yellow.
NOTe: There is no rear burner slide adjustable air shutter
for propane units.
20304685
Figure 34
VC41LDVI/VC41CDVI Gas Fireplace Insert
Slide Adjustment
Lever
FP2996
slide lever
FP2996
29