Equipment Requirements
400 MHz Pentium-based PC with a minimum of 256 MB of RAM and 50 MB of of
available hard drive space
4x CD-ROM drive
One of the following operating systems: Microsoft
800 x 600 display
®
The Bose
FreeSpace
An RS-232 serial cable, M/F with DB9 connectors
An oscilloscope
An audio signal generator similar to an Audio Precision ATS-1
A digital multimeter
Four 100 Ohm, 250 Watt load resistors
One 2 Ohm, 250 Watt load resistor
Test Strategy and Conditions
Verify the customer complaint. Read any applicable notes that came in with the unit. Then
power up the unit and attempt communication using the Bose Installer program. If successful,
examine the error log files to try to determine the nature of the failure.
The amplifier will be put into a known state for test by first updating the unit's microcode using
the Bose Installer program. This resets the unit, sets the EQ's and gains to the proper levels
and maps the Zone 1 input to Zones 1 – 4 at the outputs.
Note: Loading new host microcode will place the unit into the factory default condition and will
also erase the stored unit serial number.
Once the update is completed, the unit will need to be configured so that Zone 1 input is
mapped to the Zone 1 amplifier output, Zone 2 to Zone 2, etc. Once this is completed the
amplifier will be properly configured for test.
All AC audio measurements must be band limited to 30 kHz. AC power must be applied to the
4400 amplifier product variants as follows:
Product Code
040753
040754
040742
040755
040756
All audio inputs must be terminated with 600 Ohms. All line level outputs must be terminated
with 400 Ohms. All amplifier outputs must be terminated with 50 Ohms.

TEST PROCEDURE SETUP

®
4400 Installer™ software version 1.0 or higher
Country
US/Canada
Europe
Japan
UK/Singapore
Australia
®
®
Windows
NT, 2000 or Vista
VAC
120 VAC/60 Hz
230 VAC/50 Hz
100 VAC/60 Hz
230 VAC/50 Hz
240 VAC/50 Hz
63