This is the configuration of the two possible Maintenance Association Identifier
formats.
ITU ICC: This is defined by ITU. 'ICC' can be max. 6 char. 'MEG id' can be max. 7
char.
IEEE String: This is defined by IEEE. 'Domain Name' can be max. 8 char. 'MEG
id' can be max. 8 char.
This is either ITU ICC (MEG ID value[1-6]) or IEEE Maintenance Domain Name -
depending on 'Format'. See 'Format'.
This is either ITU UMC (MEG ID value[7-13]) or IEEE Short MA Name -
depending on 'Format'. See 'Format'. In case of ITU ICC format this can be max.
7 char. If only 6 char. is entered the MEG ID value[13] will become NULL.
This value will become the transmitted two byte CCM MEP ID.
Fault Cause indicating that a CCM is received with a lower level than the
configured for this MEP.
Fault Cause indicating that a CCM is received with a MEG ID different from
configured for this MEP.
Fault Cause indicating that a CCM is received with a MEP ID different from all
'Peer MEP ID' configured for this MEP.
Fault Cause indicating that AIS PDU is received.
Fault Cause indicating that LCK PDU is received.
Fault Cause indicating that server layer is indicating Signal Fail.
The consequent action of blocking service frames in this flow is active.
The consequent action of indicating Trail Signal Fail to-wards protection is active.
This box is used to mark a Peer MEP for deletion in next Save operation.
This value will become an expected MEP ID in a received CCM - see 'cMEP'.
This MAC will be used when unicast is selected with this peer MEP. Also this
MAC is used to create HW checking of receiving CCM PDU (LOC detection) from
this MEP.
Fault Cause indicating that no CCM has been received (in 3,5 periods) - from this