Gas Connection Safety - Rangemaster Classic Deluxe 90 Dual Fuel User's Manual & Installation Instructions

Hide thumbs Also See for Classic Deluxe 90 Dual Fuel:
Table of Contents

Advertisement

Fig. 1.1
L
N
10 mm² max
ArtNo.130-0010 Electrical connections single-phase
230 V ac 50 Hz
Fig. 1.2
L1
N
L3
L2
6 mm² max
3N ac
230/400 V 50 Hz
Otherwise, all installations must be in
accordance with the relevant instructions in
this booklet.
n
Note: The cooker must be connected to the
correct electrical supply as stated on the
voltage label on the cooker, through a suitable
cooker control unit incorporating a double-
6 mm² max
pole switch, having a contact separation of at
least 3 mm in all poles.
n
Access to the mains terminal is gained by
removing the electrical terminal cover box on
the back panel. Connect the mains cable to the
6 mm² max
correct terminals for your electrical supply type
(Fig. 1.1 and Fig. 1.2). Check that the links are
correctly fitted and that the terminal screws are
10 mm² max
tight. Secure the mains cable using the cable
clamp.
Minimum temperature rating T105.
Read the instructions before installing or using
this appliance.

Gas Connection Safety

2
WARNING:
THE APPLIANCE MUST BE
EARTHED.
THE COOKER MUST NOT BE
CONNECTED TO AN ORDINARY
DOMESTIC POWER POINT.
This cooker is a Class 2 Subclass 1
appliance.
This appliance can be converted for use on
another gas.
Before installation, make sure that the
cooker is suitable for your gas type and
supply voltage. See the data badge.
DO NOT use reconditioned or
unauthorised gas controls.
Disconnect from the electricity and gas
supply before servicing.
When servicing or replacing gas-carrying
components disconnect from the gas
supply before starting operation. Check
the appliance is gas sound after
completion.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Professional deluxe 90 dual fuelElan deluxe 90 dual fuelPdl90dffss-cClassic deluxeProfessional deluxeElan deluxe ... Show all

Table of Contents