Pressure Testing; Electrical Connection - Rangemaster Classic Deluxe 90 Dual Fuel User's Manual & Installation Instructions

Hide thumbs Also See for Classic Deluxe 90 Dual Fuel:
Table of Contents

Advertisement

Check the appliance is electrically safe and gas sound when you have finished.
CURRENT OPERATED EARTH LEAKAGE BREAKERS
The combined use of your cooker and other domestic
appliances may cause nuisance tripping, so we recommend
that the cooker is protected on an individual RCD (Residual
Current Device) or RCBO (Residual Current Breaker with
Overload).
IF IN DOUBT, PLEASE CONSULT A SUITABLY QUALIFIED
ELECTRICIAN.
Fig. 11.13
L
N
10 mm² max
ArtNo.130-0010 Electrical connections single-phase
230 V ac 50 Hz
Fig. 11.14
L1
N
L3
L2
6 mm² max
3N ac
230/400 V 50 Hz
INSTALLATION

Pressure Testing

The gas pressure can be measured at one of the hotplate
burner injectors (not the wok burner).
Lift off a burner head. Fit the pressure gauge to the injector.
Turn on and light one of the other hotplate burners.
Turn on the control knob for the burner with the pressure
gauge fitted to let gas through.
See the data badge for test pressures.
Turn off the burners. Make sure that you reassemble the
burner top in the correct way on the burner body.

Electrical Connection

The cooker must be installed by a qualified electrician, in
accordance with all relevant British Standards/Codes of
Practice (in particular BS 7671), or with the relevant national
and local regulations.
Note: The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker, through
6 mm² max
a suitable cooker control unit incorporating a double-pole
switch, having a contact separation of at least 3 mm in all
poles.
n
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect the
mains cable to the correct terminals for your electrical supply
type (Fig. 11.13 and Fig. 11.14). Check that the links are
correctly fitted and that the terminal screws are tight. Secure
the mains cable using the cable clamp.
6 mm² max
10 mm² max
36
The cooker must not be connected to an ordinary
domestic power point.