Procedure 6.8 - Replacing The Input Module - Precor 9.33 Manual

Hide thumbs Also See for 9.33:
Table of Contents

Advertisement

9.33, 9.35 240V Treadmill

Procedure 6.8 - Replacing the Input Module

1.
Set the treadmill circuit breaker in the "off" position and unplug the treadmill's line cord from
the AC outlet.
2.
Remove the treadmill's hood.
3.
Remove the two screws that fastens the AC input panel to the frame,. See Diagram 6.4.
4.
Lift the AC input panel from the frame and rotate it to expose the AC line cord clamp screws
and input module screws. See Diagram 6.5.
5.
Remove the hardware that retains the AC line cord clamp and remove the clamp.
6.
Disconnect the AC line cord from the input module.
7.
Disconnect the wiring from the input module (1 blue wire, 1 brown wire and 1 green/yellow
wire).
8.
Remove the hardware that retains the input module and remove the input module.
9.
Set the input module in its mounting position with the side with two terminals facing the
circuit breaker.
10. Connect the blue wire removed in step 5 to terminal "N", the brown wire to terminal "L" and
the green/yellow wire to terminal "E" of the input module. See Diagram 6.6.
Diagram 6.6 - Input Module Wiring
11. Insert the AC line cord firmly into the input module. Set the AC line cord clamp in its
mounting position and fasten it with the hardware removed in step 5.
12. Set the input panel in its mounting position and fasten it with the hardware removed in step
3.
13. Check treadmill operation per Section 3
Blue
N
E
Brown
L
Green/Yellow
Page 42

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

9.35

Table of Contents