Table Of Contents - Beckett AF44XR Instruction Manual

Oil burner, f air tube combinations voltage 120 vac / 60 hz
Hide thumbs Also See for AF44XR:
Table of Contents

Advertisement

Instruction Manual - Model AF Oil Burner
Contents
Prepare before installing
Verify specifications ................................................................................. 3
Be aware of hazard definitions .................................................................... 3
Check certifications/approvals .................................................................... 3
Notice special requirements ....................................................................... 3
Prepare burner & site
Inspect/prepare installation site .................................................................. 4
Prepare burner ........................................................................................ 5
Check/adjust "Z" dimension ....................................................................... 6
Pipe, wire, & adjust burner
Mount burner on appliance ........................................................................ 7
Connect fuel lines ................................................................................... 7
Wire burner ............................................................................................ 7
Startup & adjust burner
Startup burner/set combustion .................................................................... 9
Set combustion with instruments ................................................................. 9
Service & maintain burner
Perform regular maintenance ..................................................................... 9
To replace the blower wheel ...................................................................... 9
Replacement parts .................................................................................. 10
Owner's information.......... ....................................................................... 11
Owner service and maintenance................................................................. 12
Warranty................................................................................................12
Table 1 - Air Tube Combination (ATC) codes*
Static
Firing rate
plate
(GPH)
Head
size
(min-max)
(inches)
0.40-0.75
F0
3 ⅜ U
0.75-1.25
F3
2 ¾
0.85-1.35
F4
2 ¾
0.85-1.65
F6
2 ¾
1.10-2.00
F12
2 ¾
1.65-2.50
F22
2 ¾
2.50-3.00
F31
None
*Refer to Beckett OEM Specification Guide, Part No. 6711, for non-standard air tube combinations
2
4 ½
5 ⅜
6 ⅝
AF44XR
AF53XR
AF65XR
AF44XN
AF53XN
AF65XN
AF44WH
AF53WH
AF65WH
AF44YB
AF53YB
AF65YB
AF44XO
AF53XO
AF65XO
AF44XP
AF53XP
AF65XP
AF44XS
AF53XS
AF65XS
ATC codes for usable air tube lengths:
("A" in inches; see Figure 2, page 6)
7 ¼
9
AF72XR
AF90XR
AF72XN
AF90XN
AF72WH
AF90WH
AF72YB
AF90YB
AF72XO
AF90XO
AF72XP
AF90XP
AF72XS
AF90XS
Beckett
10 ½
13
16
AF104XR
AF130XR
AF160XR
AF104XN
AF130XN
AF160XN
AF104WH
AF130WH
AF160WH
AF104YB
AF130YB
AF160YB
AF104XO
AF130XO
AF160XO
AF104XP
AF130XP
AF160XP
AF104XS
AF130XS
AF160XS

Advertisement

Table of Contents
loading

Table of Contents