2.3.4.3

Step 3: Connect Ethernet

The ONT supports four, CAT 6, 1 Gigabit (10/100/1000 Base-T) connections (GE1 to GE4) on
the rear of the ONT. (Refer to
Connect Ethernet cables to the appropriate GE (GE1 through GE4) ports. If Ethernet cables
are not available, use the following procedure and table to create the Ethernet cables.
1. Trim the insulation for the subscriber Ethernet cable.
2. Connect the wires per the following table using an RJ-45 Crimper.

Table 5. Ethernet RJ-45 Pin-out

Ethernet RJ-45 Pin-out
Pin
1
2
3
4
5
6
7
8
3. Insert the RJ-45 Connectors in the appropriate ports, GE 1 through GE 4.
2.3.4.4

Step 4: Connect Power

Plug the supplied 12 VDC Power Adapter into the 12V connector on the rear of the chassis.
Connect the AC plug to a standard 120 VAC outlet. (Refer to
location of the Power connector.)
2.3.4.5

Step 5: Connect USB

There is a USB data connection on the rear of the ONT that can be used for connection and
communications with other computers and electronic devices. Connect the USB cable to the
USB port (Refer to
2.3.4.6

Step 6: Connect UPS (optional)

f
CAUTION!
DO NOT connect the Power Adapter and an UPS at the same time! This can damage the
ONT. The ONT can be powered by either power source, but not both simultaneously.
The UPS connects to the 8-pin MOLEX connector labeled UPS (see
offers a UPS Cable assembly (P/N 1287402G1) for this connector. (Refer to
22 for the location of the UPS connector.)
The
to the ONT by a local power source with battery backup that uses the AC power at the
61287RGONT-29C
Revision C
Name
TRD0+
TRD0-
TRD1+
TRD2+
TRD2-
TRD1-
TRD3+
TRD3-
Figure 6
can typically use an un-interruptible power supply (UPS) if desired. Power is supplied
ONT
Figure 6
on page 22 for the location of the Ethernet connectors.)
Description
Transmit/Receive Positive
Transmit/Receive Negative
Transmit/Receive Positive
Transmit/Receive Positive
Transmit/Receive Negative
Transmit/Receive Negative
Transmit/Receive Positive
Transmit/Receive Negative
on page 22 for the location of the USB connector.)
Physical Installation
Color Code
White/Orange
Orange
White/Green
Blue
White/Blue
Green
White/Brown
Brown
Figure 6
on page 22 for the
Figure
5). ADTRAN
Figure 6
on page
21