Wear Parts; Ambient Conditions - Bosch Rexroth IndraControl VDP 15.3 Multi Touch Operating Instructions Manual

Table of Contents

Advertisement

Bosch Rexroth AG

Ambient conditions

Ordering code
RKB0019/003,0 (*******-*******-*******)
RKB0019/005,0 (*******-*******-*******)
Tab. 5-5: Connecting cables to the control cabinet PC

5.6 Wear parts

Wear parts are not subject to any warranty.
Backlight
The service life of the backlight is limited. After this period, the backlight will
produce only 50 % of its original brightness. The service life is 50,000 hours if
the ambient temperature is 25 °C.
6 Ambient conditions
Max. ambient tempera-
ture
Max. temperature gradi-
ent
Humidity
Air pressure
8/37
In operation
+0 °C to +50 °C
Temporal temperature
changes up to 3 K per
minute
Min. relative humidity:
5 %
Max. relative humidity:
85 %
Min. absolute humidity:
1 g/m
3
Max. absolute humidity:
25 g/m
3
Condensation not al-
lowed
Corresponds to climatic
class 3K3 acc. to EN
60721-3-3
Up to 3,000 m above
sea level acc. to EN
61131-2
Part number
Description
R911171167
USB connecting cable,
Length 3 m
R911171168
USB connecting cable,
Length 5 m
Transport
-20 °C to +60 °C
Temporal temperature
changes up to 3 K per
minute
Min. relative humidity:
5 %
Max. relative humidity:
75 %
Min. absolute humidity:
1 g/m
3
Max. absolute humidity:
25 g/m
3
Condensation not al-
lowed
Corresponds to climatic
class 2K2 acc. to EN
60721-3-2
Up to 3,000 m above
sea level acc. to EN
61131-2
DOK-SUPPL*-VDPXX.3MTBU-IT03-EN-P
Storage
-20 °C to +60 °C
Temporal temperature
changes up to 3 K per
minute
Min. relative humidity:
5 %
Max. relative humidity:
85 %
Min. absolute humidity:
1 g/m
3
Max. absolute humidity:
25 g/m
3
Condensation not al-
lowed
Corresponds to climatic
class 1K2 acc. to EN
60721-3-1
Up to 3,000 m above
sea level acc. to EN
61131-2