Bosch Rexroth AG
Interfaces
Use a 24 V industrial power supply unit acc. to DIN EN 60742, classification VDE
0551, for example "VAP01.1H-W23-024-010-NN" (part number R911171065) for
the voltage supply.

9.4 S1 DIP switch

9.4.1 Overview

Fig. 9-3: S1 DIP switch at the connector panel of the operator display
Name at the hous-
Switch type
ing
S1/1
DIP switch
S1/2
DIP switch
Tab. 9-2: DIP switch at the VDP

9.5 USB interfaces

There are two USB interfaces on the connector panel (XUSB1/2) at the devices
and, depending on the variant, one interface on the front panel.

9.5.1 Operating USB ports at operator display

Cable length of the
XSER connection
Up to 5 meters
Up to 5 meters
From 5 to 30 meters
More than 30 meters
Tab. 9-3: USB speed depends on XSER cable length
Interference-free USB2.0 connection only up to a cable length of 5
meters.
14/37
S1
ON
1 2
OFF
Function
No function
OFF: Cable length to control cabinet PC ≤ 30 m
ON: Cable length to control cabinet PC > 30 m
DIP switch 2
USB speed
OFF
12 Mb/s
OFF
480 Mb/s
(USB2.0)
OFF
12 Mb/s
ON
12 Mb/s
Note
-
An additional USB cable between con-
trol cabinet PC and XUSBIN is required
The connected device may not contain a
USB hub
Only mouse and keyboard can be con-
nected. The connected device may not
contain a USB hub
DOK-SUPPL*-VDPXX.3MTBU-IT03-EN-P