Mounting The Device To A Panel - Siemens SIMATIC NET RUGGEDCOM RX5000 Installation Manual

Hide thumbs Also See for SIMATIC NET RUGGEDCOM RX5000:
Table of Contents

Advertisement

3.
4.
2.3.2

Mounting the Device to a Panel

For panel installations, the RUGGEDCOM RX5000 can be equipped with adapters pre-
installed on each side of the chassis. The adapters allow the device to be attached to
a panel using screws.
RUGGEDCOM RX5000
Installation Manual, 01/2021, C79000-G8976-1058-13
Insert the device into the rack.
Note
Since heat within the device is channeled to the enclosure, it is recommended
that 1 rack-unit of space, or 44 mm (1.75 in), be kept empty above the device.
This allows a small amount of convectional airflow.
Forced airflow is not required. However, any increase in airflow will result in a
reduction of ambient temperature and improve the long-term reliability of all
equipment mounted in the rack space.
Secure the adapters to the rack using the supplied hardware.
Installing the Device
2.3.2 Mounting the Device to a Panel