Ml296Dfv Gas Furnace; Shipping And Packing List; Safety - Lennox MERIT Series Installation Instructions Manual

Downflow air discharge
Table of Contents

Advertisement

ML296DFV Gas Furnace

The ML296DFV Category IV gas furnace is shipped ready
for installation in the downflow position.
The furnace is equipped for installation in natural gas
applications. A conversion kit (ordered separately) is re-
quired for use in propane/LP gas applications.
The ML296DFV can be installed as a Direct Vent or
Non- Direct Vent gas central furnace.
NOTE - In Direct Vent installations, combustion air is taken
from outdoors and flue gases are discharged outdoors. In
Non-Direct Vent installations, combustion air is taken from
indoors or ventilated attic or crawlspace and flue gases
are discharged outdoors. See FIGURE 1 and FIGURE 2
for applications involving roof termination.
DIRECT VENT INSTALLATION
EXHAUST OUTLET
COMBUSTION
AIR INTAKE OUTSIDE
OF HOUSE
FIGURE 1
NON-DIRECT VENT
INSTALLATION
EXHAUST
OUTLET
COMBUSTION
AIR INTAKE INSIDE
VENTILATED
ATTIC SPACE
FIGURE 2
NON-DIRECT VENT
INSTALLATION
EXHAUST
OUTLET
COMBUSTION
AIR INTAKE
INSIDE
OF HOUSE
NON-DIRECT VENT
INSTALLATION
EXHAUST
OUTLET
COMBUSTION
AIR INTAKE INSIDE
VENTILATED
CRAWL SPACE
Page 3

Shipping and Packing List

Package 1 of 1 contains
1 - Assembled ML296DFV unit
1 - Bag assembly containing the following:
1 - Snap bushing
1 - Snap plug
1 - Wire tie
1 - Condensate trap
1 - Condensate trap cap
1 - Condensate trap clamp
1 - 2" diameter Air intake screen
1 - 3/4" Threaded street elbow
2 - 2" Street elbows
2 - Side vent sealing plates
2 - Side vent sealing gaskets
6 - Sheet metal screws
DANGER
Danger of explosion.
There are circumstances in which odorant used with LP/
propane gas can lose its scent. In case of a leak, LP/
propane gas will settle close to the floor and may be
difficult to smell. An LP/propane leak detector should be
installed in all LP applications.
Check equipment for shipping damage. If you find any
damage, immediately contact the last carrier.
The following items may also be ordered separately:
1 - Thermostat
1 - LP/Propane changeover kit
1 - High altitude pressure switch
Safety Information
WARNING
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional installer (or
equivalent), service agency or the gas supplier.
CAUTION
As with any mechanical equipment, personal injury can
result from contact with sharp sheet metal edges. Be
careful when you handle this equipment.
Use only the type of gas approved for use with this fur-
nace. Refer to unit nameplate. ML296DFV units are CSA
International certified to ANSI Z21.47 and CSA 2.3 stan-
dards.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ml296dfv

Table of Contents