Lennox MERIT Series Installation Instructions Manual page 23

Downflow air discharge
Table of Contents

Advertisement

Maximum Allowable Exhaust Vent Pipe Length (in ft.) Without Insulation In Unconditioned Space For
Winter Design
Vent Pipe
Tempera-
Diameter
tures1 °F (°C)
2 in
32 to 21
(0 to -6)
2-1/2 in
3 in
2 in
20 to 1
2-1/2 in
(-7 to -17)
3 in
2 in
0 to -20
2-1/2 in
(-18 to -29)
3 in
1Refer to 99% Minimum Design Temperature table provided in the current edition of the ASHRAE Fundamentals Handbook.
2 Poly-Propylene vent pipe (PP) by Duravent and Centrotherm.
NOTE - Concentric terminations are the equivalent of 5' and should be considered when measuring pipe length.
NOTE - Maximum uninsulated vent lengths listed may include the termination(vent pipe exterior to the structure) and cannot exceed
5 linear feet or the maximum allowable intake or exhaust vent length listed in TABLE 7 or TABLE 8 which ever is less.
NOTE - If insulation is required in an unconditioned space, it must be located on the pipe closest to the furnace. See FIGURE 27.
Winter Design Temperatures Two - Stage High Efficiency Furnace
045
PVC
21
16
12
11
7
2
6
1
1
Conditioned
Space
TABLE 9
Unit Input Size
070
PP
PVC
2
18
33
n/a
26
12
21
9
19
n/a
14
2
9
4
12
n/a
7
1
2
Conditioned
Space
Pipe Insulation
Unconditioned
Space
FIGURE 27
Page 23
090
PP
PVC
2
30
46
n/a
37
21
30
17
28
n/a
21
9
16
10
19
n/a
13
2
8
Exhaust
Pipe
Intake
Pipe
PP
2
42
n/a
30
25
n/a
16
16
n/a
8