Danger!
Risk of personal injury and equipment damage due to improper operation
Risk of death from improper operation!
Make sure that only users who are users as defined in the user section use the
Children must be supervised to ensure that they do not play at or with the unit.
Danger!
Risk of personal injury and equipment damage due to leaking refrig- erant
In accordance with DIN EN 378 standard, part 1, the refrigerant used with this unit, R290
(propane), is classified as safety group A3. It is not poison- ous and not caustic or
corrosive. However, it is combustible and highly flammable. As a result, a potentially
explosive atmosphere may occur in the case of leaks.
The refrigerant is heavier than air and, consequently, accumulates at the bottom and may enter
lower lying areas (e.g. sewage systems). At high concentrations, this may lead to a lack of
oxygen, resulting in a risk of suf- focation. Lower concentrations may have a narcotic effect. The
refrigerant has a very slight, somewhat sweet smell.
Avoid any damage to components that carry the refrigerant
If you suspect any leaks, however small, shut down the unit, air the room well and
Do not allow direct contact with the skin of any leaking refrigerant.
Fire, open flames and smoking are prohibited.
If you begin to notice any smell, leave the room and alert the fire ser- vice
Notice!
In particular, safety standards are to be observed in their scope of validity (e.g. EN 60335-2-
75).
2

Transport and packaging

Choose a suitable packaging when returning the unit itself or one of its components to Cornelius
Deutschland GmbH, e.g. for repairs. In particular, make sure that the unit and any components are
protected from shock/impact, moisture, dirt and electrostatic discharge (ESD). This will prevent transport
damage to the unit and to the components, for which the manufacturer shall assume no liability.
Caution!
Component damage due to freezing liquids
Ambient temperatures that are below freezing will lead to the freezing of any water or cleaning
agent residue remaining inside the unit. This will lead to damages of internal components.
Before shipment, storage or relocation of the unit, the unit is to be cleaned and the cleaning
solution is to be fully drained from the unit.
2.1

Storage

Avoid excessive temperature fluctuations as condensate may form, which in turn may cause damage to
the unit or to the components.
The permissible storage temperature is -10 °C to +50 °C.
The acclimatization period is 6 hours.
Cornelius Deutschland GmbH
Document no: TD1011600EN
Version A, 04.04.2019, Index 0
unit; see chapter 1.3.2, page 5.
inform your service partner.