Wiring; Operation; Lubrication - Campbell Hausfeld IN629500AV Operating Instructions And Parts Manual

Campbell hausfeld portable garage air compressor operating instructions and parts manual
Table of Contents

Advertisement

Available languages

Available languages

Operating Instructions and Parts Manual
Installation (Continued)

WIrIng

1. Local electrical wiring codes differ from area to area. Source
wiring, plug and protector must be rated for at least the
amperage and voltage indicated on motor nameplate, and
meet all electrical codes for this minimum.
2. Use a slow blow fuse or a circuit breaker.
Overheating, short circuiting and fire damage
will result from inadequate wiring, etc.
NOTE: 120 volt, 15 amp units can be operated on a 120 volt
circuit under the following conditions:
a. No other electrical appliances or lights are connected to
the same branch circuit.
b. Voltage supply is normal.
c. Circuit is equipped with a 15 amp circuit breaker or a 15
amp slow blow fuse.
3. If these conditions cannot be met or if nuisance tripping
of current protection device occurs, it may be necessary to
operate compressor from a 120 volt, 20 amp circuit.

Operation

MoISture In CoMPreSSeD AIr
Moisture in compressed air will form into droplets as it
comes from an air compressor pump. When humidity is
high or when a compressor is in continuous use for an
extended period of time, this moisture will collect in the
tank. When using a paint spray or sandblast gun, this water
will be carried from the tank through the hose, and out of
the gun as droplets mixed with the spray material.
IMPORTANT: This condensation will cause water spots
in a paint job, especially when spraying other than water
based paints. If sandblasting, it will cause the sand to cake
and clog the gun, rendering it ineffective. A filter in the air
line (MP3105), located as near to the gun as possible, will
help eliminate this moisture.
This compressor can be used for general inflation as well as
intermittent duty air tool usage. For inflation purposes, this
compressor utilizes a new technology called Rapid Inflation
Technology (RIT).
IMPORTANT: Make sure the Wheel Lock/Foot Brake is engaged
before operating the unit (See Figure 11).

LubrICAtIon

This is an oilless product and DOES NOT require lubrication to
operate.
12
www.chpower.com
Outlet (Tool)
Pressure Gauge
Click-to-set
regulator
ASME
Safety Valve
Figure 13
Storage Trays
Tank
Pressure
Gauge

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wl6700 series

Table of Contents