Campbell Hausfeld HJ3001 Series Operating Instructions Manual

Campbell Hausfeld HJ3001 Series Operating Instructions Manual

200 psi portable asme
Hide thumbs Also See for HJ3001 Series:
Table of Contents

Advertisement

Available languages

Available languages

See warranty on page 8 for important information about commercial use of this product.
operating instructions
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Description
Portable oilless air compressors are for
home and workshop use. Cleaning or
replacement of the inlet filter on all
models and draining moisture from the
air receivers are required maintenance.
Safety Guidelines
This manual contains information
that is very important to know
and understand. This information
is provided for SAFETY and to
PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates
an imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates
a potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates
a potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
Unpacking
When unpacking unit, inspect carefully
for any damage that may have occurred
during transit. Make sure any loose
fittings, bolts, etc., are tightened before
putting unit into service. In case of
questions, damaged or missing parts,
please call 1-800-543-6400 for customer
assistance. Have the serial number,
model number, and parts list (with
missing parts circled) before calling.
© 2010 Campbell Hausfeld/Scott Fetzer
Record the Model No., Serial No. and
date of purchase in the space below.
Model No.
Serial No.
Date of purchase _________________
Retain these numbers for future
STOP!
shipping, handling or use. Damage may
result in bursting and cause injury or
property damage.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
For parts, product & service information,
visit www.chpower.com
hG3000 Series, hJ3001 Series, hJ3002 Series
200 pSi portable aSMe
______________________
______________________
reference.
Do not retUrn
the proDUct to
the retailer!
Do not operate unit
if damaged during

air compressors

Breathable Air Warning
this compressor / pump is not
equipped and should not be
used "as is" to supply breathing
quality air. For any application of
air for human consumption, the
air compressor / pump will need
to be fitted with suitable in-line
safety and alarm equipment.
this additional equipment is
necessary to properly filter
and purify the air to meet
minimal specifications for Grade
D breathing as described in
compressed Gas association
commodity Specification G
7.1 - 1966, oSha 29 cFr 1910.
134, and / or canadian Standards
associations (cSa).
DiSclaiMer oF warrantieS
in the event the compressor is
used for the purpose of breathing
air application and proper in-line
safety and alarm equipment is
not simultaneously used, existing
warranties shall be voided, and
the campbell hausfeld disclaims
any liability whatsoever for any
loss, personal injury or damage.
reaD & Follow all inStrUctionS
Save theSe inStrUctionS
Do not DiScarD
IN634100AV 7/10

Advertisement

Table of Contents
loading

Summary of Contents for Campbell Hausfeld HJ3001 Series

  • Page 1: Air Compressors

    REMINDER: Keep your dated proof of purchase for warranty purposes! © 2010 Campbell Hausfeld/Scott Fetzer hG3000 Series, hJ3001 Series, hJ3002 Series 200 pSi portable aSMe Record the Model No., Serial No. and date of purchase in the space below.
  • Page 2: California Proposition

    Disconnect power and depressurize system before servicing air compressor! 9. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA).
  • Page 3: Spraying Precautions

    8. Do not direct airstream at body. hG3000 Series, hJ3001 Series, hJ3002 Series assembly aSSeMblY toolS reqUireD Tools (not provided) for assembly: (1) #2 Phillips screwdriver...
  • Page 4: Electrical Installation

    Operating Instructions introduction pressure Switch - ON/OFF Switch - In the ON position, the compressor shuts off automatically when tank pressure reaches the maximum preset pressure. In the OFF position, the compressor will not operate. This switch should be in the OFF position when connecting or disconnecting the power cord from the electrical outlet or when changing air...
  • Page 5: Grounding Instructions

    Series, hJ3001 Series, hJ3002 Series 3. If above conditions cannot be met or if nuisance tripping of current protection device occurs, it may be necessary to operate compressor from a 120 volt, 20 amp circuit.
  • Page 6: Operation

    Operating Instructions operation beFore FirSt Start-Up break-in proceDUre (Complete this procedure before using compressor for the first time. Once completed, it is not necessary to repeat.) 1. Turn regulator knob fully clockwise (to the right) to open air flow and open drain valve.
  • Page 7: Troubleshooting Chart

    Air output lower 1. Broken inlet valves than normal 2. Intake filter dirty 3. Connections leaking hG3000 Series, hJ3001 Series, hJ3002 Series 2. Wrong gauge wire or length of extension cord. 3. Clogged air filter. 4. Lack of proper ventilation.
  • Page 8: Limited Warranty

    2. WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400. 3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld compressor.
  • Page 9: Directives De Sécurité

    MÉMento: Gardez votre preuve datée d'achat à fin de la garantie! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. © 2010 Campbell Hausfeld/Scott Fetzer Série hG3000, Série hJ3001, Série hJ3002 compresseurs d'air aSMe portables 1 379 kpa Enregistrer le N°...
  • Page 10: Généralités Sur La Sécurité

    Instructions d’Utilisation Généralités Sur la Sécurité propoSition 65 caliFornie Ce produit ou son cordon peuvent contenir des produits chimiques, y compris du plomb, relevés par l'État de Californie comme cause de cancer, d'anomalies congénitales ou d'autres problèmes reproductifs. Lavez-vous les mains après toute manipulation.
  • Page 11: Précautions De Pulvérisation

    Généralités Sur la Sécurité (Suite) 19. NE JAMAIS rajuster la soupape de sûreté ou le manostat. Garder la soupape de sûreté libre de peinture et autres accumulations. Ceci sert à éviter la sur-pression. Ne jamais enlever ou essayer d’ajuster la soupape de sûreté. Tenir la soupape de sûreté...
  • Page 12 Instructions d’Utilisation introduction Manostat - Interrupteur ON/OFF – Dans la position ON, le compresseur se coupe automatiquement quand la pression du réservoir arrive à la pression maximale réglée d’avance. Dans la position OFF, le compresseur ne fonctionnera pas. Cet interrupteur devrait être dans la position OFF pendant le branchement ou le débranchement du cordon d’alimentation de la prise de courant...
  • Page 13 installation (Suite) inStallation De FilS 1. Les codes électriques d’installation de fils sont variables d’un endroit à l’autre. Les fils d’alimentation, fiche et protecteurs doivent êtres classifiés pour au moins l’ampérage et la tension indiqués sur la plaque indicatrice et doit repondre aux codes électriques pour ce minimum.
  • Page 14 Instructions d’Utilisation Functionnement avant le preMier DÉMarraGe procÉDUre De rôDaGe Cette procédure doit être terminée avant d'utiliser le compresseur pour la première fois. Ensuite, il n'est pas nécessaire de la refaire. 1. Tourner le bouton du régulateur complètement vers la droite, dans le sens des aiguilles d'une montre pour ouvrir la circulation d'air et ouvrez le robinet de vidange.
  • Page 15: Entretien

    entretien SoUpape De SÛretÉ aSMe Ne jamais enlever ou essayer d’ajuster la soupape de sûreté! Tenir la soupape de sûreté libre de peinture et d’autres accumulations. Vérifier la soupape de sûreté de la manière suivante : 1. Brancher le compresseur et le faire fonctionner jusqu'à...
  • Page 16: Guide De Dépannage

    Instructions d’Utilisation Guide De Dépannage Symptôme cause(s) possible(s) Compresseur ne 1. Perte de puissance ou surchauffage fonctionne pas 2. Manque de puissance électrique 3. Fusible sauté 4. Disjoncteur déclenché 5. Surcharge thermique déclenché 6. Manostat en panne Le moteur ronron 1.
  • Page 17 Série Série Série hG3000, hJ3001, hJ3002 notes 17 Fr...
  • Page 18: Garantie Limitée

    9. RESPONSABILITÉS DE L’ACHETEUR AUX TERMES DE CETTE GARANTIE: A. Fournir une preuve d’achat datée et un état d’entretien. B. La livraison ou expédition des compresseurs portatifs ou des pièces détachées au Centre De Service Autorisé Campbell Hausfeld. Taux de frais, si applicables, sont la responsabilité de l’acheteur.
  • Page 19: Medidas De Seguridad

    1-800-543-6400 por asistencia al cliente. recorDatorio: ¡Guarde su comprobante de compra con fecha para fines de la garantía! adjúntela a este manual o archívela en lugar seguro. © 2010 Campbell Hausfeld/Scott Fetzer Serie portátiles aSMe de 13,79 bar Registre en el espacio a continuación el No.
  • Page 20 Manual de Instrucciones Generales de Seguridad propoSiciÓn De caliFornia 65 Este producto o su cable de corriente pueden contener químicos, incluido plomo, que es conocido por el Estado de California como causante de cáncer y defectos de nacimiento u otros daños reproductivos.

This manual is also suitable for:

Hg3000 seriesHj3002 seriesIn634100av

Table of Contents