Invacare AVIVA RX Series Service Manual page 20

Hide thumbs Also See for AVIVA RX Series:
Table of Contents

Advertisement

Invacare® AVIVA™ RX series
Problem
Motors stop and start
again
Motor runs but loses
power
Motors stop and do
not start again
Motors lose power
while driving
Motor judders or runs
irregularly, or only
one motor runs
Motors do not run
20
Other symptoms
Possible cause
None
Voltage decline
None
High motor load
allows power module
to lower voltage
None
High motor load
allows power module
to lower voltage
None
Circuit breaker
switched off
None
Motor defective
None
Power module
defective
None
Bad connections
None
Clutch(es) defective
Bearing defective
Collector defective
None
Bad connections
Circuit breaker
switched off
Batteries defective
Cabling to power
module or remote
defective
Power module
defective
Corroded contacts
Contacts defective
Documentation
Solution
Stop driving and allow
electronics to cool
down.
Stop driving and allow
electronics to cool
down.
Leave mobility device
switched on and
let power module
operate. Charge
batteries overnight
with electronics
turned on.
Check cabling and
See 6.12.6 Checking
switch on circuit
Cables, page 62 and
breaker.
user manual.
Measure internal
See 5.1 Testing
Motor, page 15
resistance of motor,
and 6.9.1 Replacing
replace motor if
defective.
Motor-Gearbox Unit,
page 37.
Replace power
See 6.11.1 Replacing
module
Power Module, page
54.
Turn off electronics,
See 6.12.6 Checking
wait 10 seconds, turn
Cables, page 62.
on electronics. Check
all cabling.
Replace clutch.
See 6.9.1 Replacing
Motor-Gearbox Unit,
page 37.
Replace motor.
See 6.9.1 Replacing
Motor-Gearbox Unit,
page 37.
See 5.1 Testing
Measure internal
resistance of motor,
Motor, page 15
replace motor if
and 6.9.1 Replacing
Motor-Gearbox Unit,
defective.
page 37.
Check all cabling.
See 6.12.6 Checking
Cables, page 62.
Check cabling and
See 6.12.6 Checking
switch on circuit
Cables, page 62 and
breaker.
user manual.
Replace batteries.
See 6.12 Batteries,
page 58.
Check cabling.
See 6.12.6 Checking
Cables, page 62.
Replace power
See 6.11.1 Replacing
module.
Power Module, page
54.
Check cabling, replace
See 6.12.6 Checking
if necessary.
Cables, page 62.
1654647-B