When feed roller machanism (A, Fig. 27) and/or puller shaft cylinder assembly (B, Fig. 27) has been
removed or replaced, 1/64" (0.4mm) clearance should be maintained between upper connection (C,
Fig. 27) and floating feed roller connection (D, Fig. 27) when feed roller mechanism is in up position.
Turn off air supply to puller shaft air cylinder assembly (B, Fig. 27). Loosen screw (E, Fig. 27). Lift
feed roller mechanism (A, Fig. 27) until there is 1/64" (0.4mm) clearance between upper connection (C,
Fig. 27) and floating feed roller connection (D, Fig. 27). Slide roller stop collar (F, Fig. 27) and rubber
washer (H, Fig. 27) up until they contact the underside of head assembly (G, Fig. 27). Retighten screw
(E, Fig. 27).
ADJUSTING STOP COLLAR ON FEED ROLLER
FOR PNEUMATIC MACHINES
Fig. 27