Maintenance - Campbell Hausfeld IN203203AV 11/00 Operating Instructions Manual

Oilless compressor
Table of Contents

Advertisement

Available languages

Available languages

Operation
(Continued)
TANK PRESSURE GAUGE
Gauge shows pressure in tank
indicating compressor is building
pressure properly.

Maintenance

WARNING
!
Disconnect power
source then release all
pressure from the
system before
attempting to install, service, relocate
or perform any maintenance.
The compressor should be checked
often for any visible problems and the
following maintenance procedures
should be performed each time the
compressor is used.
1. Pull ring on safety valve and allow it
to snap back to normal position.
Safety valve must
WARNING
!
be replaced if it
cannot be actuated or it leaks air after
ring is released.
2. With compressor shut off and
pressure released: Drain moisture
from tank by opening drain cock
underneath tank.
Notes
Figure 8
3. Turn power OFF and clean dust and
dirt from motor, tank, air lines and
pump cooling fins.
IMPORTANT: Unit should be located as
far from spraying area as hose will
allow to prevent over-spray from
clogging filter.
AIR FILTER
Check air filter to be sure it is clean. To
service a filter, remove the filter
housing cover. Remove filter and clean
in hot, soapy water (Paper filters cannot
be washed). Rinse and let dry. Replace
air filters that cannot be cleaned. Place
filter back in the housing base. Replace
cover.
LUBRICATION
This is an oilless type compressor
requiring no lubrication.
THERMAL OVERLOAD PROTECTOR
This compressor is
CAUTION
!
equipped with an
automatic reset thermal overload
protector which will shut off motor if it
becomes overheated.
5
If thermal overload protector shuts
motor OFF frequently, look for the
following causes.
1. Low voltage.
2. Clogged air filter.
3. Lack of proper ventilation.
If the thermal
CAUTION
!
overload protector
is actuated, the motor must be allowed
to cool down before start-up is possible.
The motor will automatically restart
without warning if left plugged into
electrical outlet and unit is turned on.
TORQUE REQUIREMENTS
Connecting rod bolt . . . . . . . . 20 in. Ibs.
Compressor hd. bolts. . . 100-110 in. Ibs.
Motor bolts . . . . . . . . . . . . . . . 35 in. Ibs.
Mounting bolts . . . . . . . . . . . . 90 in. Ibs.
STORAGE
1. When not in use, hose and
compressor should be stored in a cool
dry place.
2. Tank should be drained of moisture.
3. Hose should be disconnected and
hung open, ends down, to allow any
moisture to drain.