Assembly
ELECTRICAL INSTALLATION
(Continued)
Grounding
All
adding oil gradually and checking the
Pin
wiring
oil level with the sight glass several
TEST
RESET
and electrical connections should be
times. Add enough oil to reach the
performed by a qualified electrician.
Installation must be in accordance with
"max" level on the sight glass. Proper
Grounded Outlet
local codes and national electrical
oil level is illustrated in Figure 1.
codes.
Figure 3 - Grounding Method
INTAKE FILTER
WIRING
Thread the intake air filter into the
Plug must be plugged into an outlet
1. Local electrical wiring codes differ from
threaded opening in the side of the
that is properly installed and
area to area. Source wiring, plug and
compressor head as illustrated in
grounded in accordance with all local
protector must be rated for at least the
Figure 2. Tighten gently with a wrench.
codes and ordinances.
amperage and voltage indicated on
Installation
motor nameplate, and meet all
Extension cords for
120V/15 Amp Unit
electrical codes for this minimum.
LOCATION
2. Use a slow blow fuse or a circuit
Length of Cord (ft)
25
50
100
It is extremely important to install the
breaker.
Gauge of Cord
14
12
10
compressor in a clean, well ventilated
3. This product is for use on a nominal
area where the surrounding air
120 volt circuit and has a grounding
temperature will not be more than
plug that looks like the plug
100°F.
illustrated in Figure 3. Make sure the
Overheating, short circuiting and fire
A minimum clearance of 18 inches
damage will result from inadequate
product is connected to an outlet
between the compressor and a wall is
wiring.
having the same configuration as the
required because objects could obstruct
plug. This product must be
Operation
air flow.
grounded. In the event of an
Do not
•Pressure Switch - Auto/Off Switch
electrical short circuit, grounding
locate
(Figure 5) - In the AUTO position, the
reduces risk of electrical shock by
the compressor air inlet near steam,
compressor shuts off automatically
providing an escape wire for electric
paint spray, sandblast areas or any
when tank pressure reaches the
current. This product is equipped
other source of contamination. This
maximum preset pressure. In the OFF
debris will damage the motor.
with a cord having a grounding wire
position, the compressor will not
with an appropriate grounding plug.
operate. This switch should be in the
OFF position when connecting or
disconnecting the power cord from
the electrical outlet or when changing
Handle
air tools.
Regulator
Safety valve
Figure 5 - Auto/Off switch
Intake filter
Motor reset
• Regulator - The regulator controls
the amount of air pressure released
at the hose outlet.
• ASME Safety Valve - This valve
automatically releases air if the tank
pressure exceeds the preset maximum.
Drain valve
Oil drain plug
Sight glass
Figure 4 - Unit Identification
www.chpower.com
3