Campbell Hausfeld Oil-Lubricated Compressor HL5403 Operating Instructions And Parts List Manual

Oil-lubricated compressor
Hide thumbs Also See for Oil-Lubricated Compressor HL5403:

Advertisement

Notes
Notas
HL5403, HL5404
32
See Warranty on page 10 for important information about commercial use of this product.
Operating Instructions and Parts List
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Oil Lubricated Compressors
Description
This oil-lubricated compressor is
STOP!
designed for do-it-yourselfers with a
variety of home and automotive jobs.
These compressors power spray guns,
impact wrenches and other tools.
Compressed air from this unit will
contain moisture. Install a water filter or
air dryer if application requires dry air.

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
Record the Model No., Serial No. and
date of purchase located on the base
To help recognize this information,
below the pump in the space below.
observe the following symbols.
Danger
Model No. ____________________
indicates
Serial No. ____________________
an imminently hazardous situation
which, if not avoided, WILL result in
Date of purchase _________________
death or serious injury.
Warning
Retain these numbers for future
indicates
reference.
a potentially hazardous situation
which, if not avoided, COULD result in
Have the serial number, model number,
death or serious injury.
and parts list (with missing parts circled
Caution
before calling.)
indicates
a potentially hazardous situation
General Safety
which, if not avoided, MAY result in
minor or moderate injury.
Information
Notice
indicates
important information, that if not
unit if damaged during shipping,
followed, MAY cause damage to
handling or use. Damage may result in
equipment.
bursting and cause injury or property
Unpacking
damage.
After unpacking the unit, inspect
carefully for any damage that may have
unattended. Leaving compressor in
occurred during transit. Make sure to
AUTO position may allow it to turn on
tighten fittings, bolts, etc., before
inadvertently. To prevent this and
putting unit into service. In case of
possible damage from power surge,
turn to OFF position after each use.
questions, damaged or missing parts,
please call 1-800-543-6400 for customer
assistance.
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2008
HL5403, HL5404
DO NOT RETURN THE
PRODUCT TO THE
RETAILER!
Breathable Air Warning
This compressor/pump is not
equipped and should not be used
"as is" to supply breathing quality
air. For any application of air for
human consumption, the air
compressor/pump will need to be
fitted with suitable in-line safety
and alarm equipment. This
additional equipment is necessary
to properly filter and purify the air
to meet minimal specifications for
Grade D breathing as described in
Compressed Gas Association
Commodity Specification G 7.1 -
1966, OSHA 29 CFR 1910. 134,
and/or Canadian Standards
Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is used
for the purpose of breathing air
application and proper in-line
safety and alarm equipment is not
simultaneously used, existing
warranties shall be voided, and the
manufacturer disclaims any liability
whatsoever for any loss, personal
injury or damage.
CALIFORNIA PROPOSITION 65
Do not
operate
You can create dust when
you cut, sand, drill or grind
materials such as wood,
paint, metal, concrete, cement, or other
masonry. This dust often contains
Do not
chemicals known to cause cancer, birth
run
defects, or other reproductive harm.
Wear protective gear.
or its power cord contains lead, a
chemical known to the State of
California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
IN626400AV 6/08
This
product

Advertisement

Table of Contents
loading

Summary of Contents for Campbell Hausfeld Oil-Lubricated Compressor HL5403

  • Page 1: Safety Guidelines

    Notes Notas See Warranty on page 10 for important information about commercial use of this product. HL5403, HL5404 Operating Instructions and Parts List Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.
  • Page 2: General Safety Information

    STOP the Information (Continued) engine/motor and check immediately for the cause. Vibration Since the air compressor and other is generally a warning of trouble. components (filters, lubricators, hoses, etc.) used, make up a high pressure 11. To reduce fire hazard, keep...
  • Page 3: Operation

    Garantía Limitada 1. DURACIÓN: A partir de la fecha de compra por el comprador original: Un Año. 2. QUIEN OTORGA ESTA GARANTÍA (EL GARANTE: Campbell Hausfeld / The Scott Fetzer Company 100 Production Drive, Harrison, Ohio 45030 Teléfono: (800) 543-6400 3.
  • Page 4: Maintenance

    Oil Lubricated Compressors Operation (Continued) MOISTURE IN COMPRESSED AIR Moisture in compressed air will form into droplets as it comes from an air 6. Unplug power cord. compressor pump. When humidity is high or when a compressor is in The compressor is now ready for use. continuous use for an extended period of time, this moisture will collect in BEFORE EACH START-UP the tank.
  • Page 5: Guía De Diagnóstico De Averías

    Compresor lubricado con aceite Guía de diagnóstico de averías Problema Posible(s) Causa(s) Acción a tomar El compresor no funciona 1. El interruptor está en la posición OFF 1. Asegúrese de que el compresor esté enchufado y que el interruptor esté en la posición ON (encendido). (apagado) 2.
  • Page 6: Troubleshooting Chart

    Oil Lubricated Compressors Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Compressor will not run 1. Switch in OFF position 1. Make sure compressor is plugged in and switch is ON. 2. No electrical power at wall outlet 2. Check circuit breaker or fuse at electrical panel. 3.
  • Page 7 Compresor lubricado con aceite 26 Sp Troubleshooting Chart (Continued) Symptom Possible Cause(s) Corrective Action Tank pressure drops 1. Loose drain valve 1. Tighten. when compressor shuts 2. Check valve leaking 2. Remove check valve. Clean or replace. 3. Loose connections at fittings, tubing, 3.
  • Page 8 Oil Lubricated Compressors Funcionamiento (Continuacíon) Se debe reemplazar la válvula de seguridad si no se puede accionar o si tiene una fuga de aire después de liberar el anillo. 1. Apague el compresor y libere la Cuando se abra la fválvula de seguridad con presión en el tanque, se liberará...
  • Page 9: Mantenimiento

    Compresor lubricado con aceite Funcionamiento HUMEDAD EN EL AIRE COMPRIMIDO La humedad que se acumula en el aire comprimido se convierte en gotas a medida que (Continuacíon) sale del cabezal del compresor de aire. Cuando el nivel de humnedad es muy alto o Nunca cuando el compresor ha estado en uso continuo por mucho tiempo, ésta se acumulará...
  • Page 10 2. WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld / Scott Fetzer Company, 100 Production Drive, Harrison, Ohio, 45030, Telephone: (800) 543-6400 3. WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser (other than for purposes of resale) of the Campbell Hausfeld compressor.
  • Page 11: Instalación

    Compresor lubricado con aceite Informaciones compresor cerca de gases o vapores inflamables. Nunca almacene líquidos o Generales de Seguridad gases inflamables cerca del compresor. (Continuacíon) Las piezas del compresor Este podrían estar calientes, inclusive cuando la unidad esté apagada. producto o su cable de corriente contienen plomo, un químico que es 9.
  • Page 12: Medidas De Seguridad

    Compresseur Graissé par l’Huile Généralités sur la Sécurité (Suite) Les moteurs, l’équipement électrique et les commandes déformations congénitales ou autres peuvent provoquer des arcs électriques problèmes de la reproduction. Portez qui enflammeront les vapeurs ou les de l’équipement de protection. gaz inflammables.
  • Page 13 A. Fournir une preuve d’achat datée et un état d’entretien. B. La livraison ou expédition des compresseurs portatifs ou des pièces détachées au Centre De Service Autorisé Campbell Hausfeld le plus près. Frais de transport, si applicables, sont la responsabilité de l’acheteur.
  • Page 14 Compresseur Graissé par l’Huile Fonctionnement (Suite) L’HUMIDITÉ DANS L’AIR COMPRIMÉ • Poignée - Conçue pour le L’humidité dans l’air comprimé forme des goutelettes en arrivant de la pompe déplacement du compresseur. du compresseur. Si l’humidité est élevée ou si le compresseur est utilisé Ne jamais utiliser la poignée sur les continuellement, cette humidité...
  • Page 15: Guide De Dépannage

    Compresseur Graissé par l’Huile Guide de Dépannage Symptôme Cause(s) Possible(s) Mesures Correctives Le compresseur ne 1. Interrupteur à la position OFF (arrêt) 1. S’assurer que le compresseur est branché et fonctionne pas l’interrupteur à ON (marche). 2. Aucun courant à la prise 2.
  • Page 16 Compresseur Graissé par l’Huile 16 Fr Pour les Pièces de Rechange, Appeler 1-800-543-6400 Fournir l’information suivante : -Numéro du modèle -Numéro de série (s’il y en a un) -Description de la pièce et son numéro tel qu’indiqué sur la liste de pièces Nº.

This manual is also suitable for:

Hl5404

Table of Contents