Location Requirements
The area in which the dryer is located must be
kept clear and free from combustible materials,
gasoline and other flammable vapors and liquids.
A dryer produces combustible lint so the area
around the dryer must be cleaned regularly to
keep it free of lint.
This dryer can only be vented from the rear and
must be exhausted to the outdoors.

Alcove or Closet Installation

WARNING
The top opening area in the door must be a minimum of 48 square inches (310cm2) and the
bottom opening area must have a minimum of 24 square inches (155cm2). These openings must
never be obstructed (a louvred door with the minimum air opening is acceptable). Minimum
installation clearances are required but more clearance is recommended.
1" (25mm)
1" (25mm)
When installing a dryer in a closet/alcove it must be
exhausted to the outdoors. No other fuel burning
appliance can be installed in the same closet or alcove.
1" (25mm)
min 2" (50mm) min 3" (76mm)
48 sq" (310cm
24 sq" (155cm
min 56 5/16"
(1430mm)
2
)
total ventation area
2
72 sq" (465cm
)
2
)
EN
11