All External Venting Systems should be:

• Made from 100 mm diameter flexible foil sleeved with a galvanised metal pipe where the vent system goes
through the wall, or 100 mm diameter galvanised metal piping.
• Exhausted outside and not into another confined space, eg the roof cavity of a house.
• Fitted with a vent cap outside to stop rain water entering the dryer exhaust system.
• Angled to avoid condensation running back into the dryer.
• The vent system should be a maximum of 2 metres with no more than three 90° bends.
• Vent systems over 2 metres long require special installation. Contact a Fisher & Paykel trained and supported
service technician.

Internal venting

The dryer is set up in the factory for front venting. If front venting is used there must be adequate ventilation to avoid the
build up of moisture in the room, which can affect the performance of the dryer. Venting must comply with local by-laws
and regulations.

Installation options

There are two different ways your dryer can be positioned. Freestanding or inverted and mounted on a wall.

Free Standing

The dryer stands on the floor and can easily be moved into
position.
1. Move the dryer into the desired position. Do not lift the
dryer by the top panel.
2. Have a minimum clearance on all sides of at least 20
mm.
3. Have a minimum clearance at the rear of 75 mm. The
spacers from the accessory wall mounting kit can be
used to set this distance.
4. Install the dryer on a stable and level floor.
https://producthelp.fisherpaykel.com/Manuals/Dryer_Manuals/User_Guides/428108C_Dryer/03_Installation_instructions