Guide-Ejection Assembly, Fuser Connector Assembly And Color-Registration Assembly - Oki C301 Maintenance Manual

Hide thumbs Also See for C301:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
4.2.17 Guide-ejection assembly, fuser connector
assembly and color-registration assembly
(1) Remove the left side cover, the right side cover, the rear cover and the top cover
assembly.
(2) Remove the CU/PU PCB and the low-voltage power supply.
(3) Detach the guide-ejection assembly
(4) Remove the two (silver-colored) screws
.
(5) Remove the film-power board
(6) Remove the (silver-colored) screw
(7) Remove the two (silver-colored) screws
plate-beam
.
(8) Remove the three (silver-colored) screws
and then the cover-code
.
(9) Remove the four (silver-colored) screws
44951501TH Rev.2
.
to detach the fuser connector assembly
.
to remove the image drum fan assembly
to remove the cover-beam
to remove the two torsion springs
to detach the color-registration assembly
.
and the
.
4.REPLACEMENT OF PARTS
4-15