Biasi M96A.24SM/B User Manual And Installation Instructions page 33

Hide thumbs Also See for M96A.24SM/B:
Table of Contents

Advertisement

Installation
Air intake adapter
Restrictor
Gasket
Fig. 6.9
For the correct use of the restrictors with twin
pipes refer to Tab. 6.2.
For M96A.24SM/..., M96A.28SM/...
Equivalent length
(air duct + flue duct)
Between 1 and 15 m
More than 15 m up to 30 m
Tab. 6.2
Vertical--- roof kit (Fig. 6.10)
Type C32
max =8,5 m
ø 125
Fig. 6.10
This kit allows vertical termination of the flue pipe
through the roof. The kit is 1.2 m in length. Exten-
sion pieces (Co--- axial) are also available which al-
lows the flue system to be extended to a total
overall maximum permissible length.
Optional 45˚ and 90˚ elbows can be used to offset
the flue route.
Each additional elbow reduces the overall accept-
able length of the flue system as follows:
45˚ reduce length by 0,5 m.
90˚ reduce length by 1 m.
Pluming kit (Fig. 6.11)
Co--- axial ø 60/100mm + vertical part ø 60mm (flue
outlet)
90˚=--- 0,85 m
Restrictor
ø 50 mm
45˚=--- 0,65 m
ø 55 mm
90˚=--- 1 m
Fig. 6.11
This kit allows the comburent air to be sucked up
and expel the burnt gasses directly to the outside
through a telescopic co--- axial flue (450--- 950
mm).
In the last section, the fumes are expelled through
45˚=--- 0,5 m
a vertical section.
Extensions and elbows can be added to extend
the kit's length.
The chart of Fig. 6.12 gives the allowable dimen-
sions of the ducts "a" and "b" of Fig. 6.11
Type C52
ø 60 mm
45˚=--- 0,5 m
90˚=--- 1 m
ø 60/100 mm
29