Symbols used ..........Definition of terms ........Warning notes ..........2 Safety information ..........3 Product description ..........4 GEMÜ CONEXO ............ 5 Correct use ............6 Order data ............7 Technical data ............. 8 Dimensions ............9 Manufacturer's information ........
– Lists 1.3 Definition of terms Protect against leakage! Working medium The medium that flows through the GEMÜ product. 1.4 Warning notes Danger of burning from hot surfaces! Wherever possible, warning notes are organised according to the following scheme: SIGNAL WORD...
6. Define the areas of responsibility. 7. Observe the safety data sheets. GEMÜ 0326 is a 3/2-way pilot solenoid valve. GEMÜ 0326 is 8. Observe the safety regulations for the media used. designed for mounting to a compact aluminium rail as a valve...
1. Use the product in accordance with the technical data. The GEMÜ 0326 directly controlled 3/2-way pilot solenoid valve is designed for mounting to a compact aluminium rail as a valve battery for mounting in control cabinets or as a valve manifold near the pneumatic components to be controlled.
Multi-port version (only electrical connection 05 and for control func- 4 Connection type Code tion 1, normally closed) Connection for GEMÜ battery rail ATEX silencer 5 Valve body/solenoid material Code (only electrical connection 05 and for control func-...
Page 8
Pilot solenoid valve, directly controlled, mounting to battery rail 2 DN DN 2 3 Body configuration Multi-port version 4 Connection type Connection for GEMÜ battery rail 5 Valve body/solenoid material PA, polyamide 6 Seal material 7 Control function Normally closed (NC) 8 Voltage/Frequency...
Type examination certificate: PTB 03 ATEX 2018 X 7.5 Mechanical data Weight: 150 g Corrosion KBK 2 resistance class: Isolation class: Protection class: IP 65 Max. switching fre- 5 Hz quency: Switching times: 11 ms Off: 20 ms www.gemu-group.com 9 / 20 GEMÜ 0326...
Page 10
DC coils are used for the AC version of normally open (NO) solenoid valves. For these AC applications with normally open (NO) valves a plug with an integrated bridge rectifier must be used (e.g. GEMÜ 1221 000 Z 0012 230 50/60). GEMÜ 0326 10 / 20 www.gemu-group.com...
(Z-1) x 32,5 + (2 x 25,5) = (181) ø 4,2 81,5 Blanking plate * Female thread M4 for the connection of Z = Number of valve seats/valves, (maximum 10 valves possible) the potential equalisation acc. to ATEX Dimensions in mm www.gemu-group.com 11 / 20 GEMÜ 0326...
1. Ensure the suitability of the valve for each respective use. 4. Do not store solvents, chemicals, acids, fuels or similar The valve must be appropriate for the piping system oper- fluids in the same room as GEMÜ products and their spare ating conditions (medium, medium concentration, temper- parts.
O-rings CAUTION Power supply varies dependent on the design (see ● product label). Fig. 1: Installation - GEMÜ 0326 Do not bridge terminals! ● 1. Remove knurled nut 10. Required for electrical connection: 2. Pull solenoid from valve body. •...
Solenoid housing 0.3 Nm). 11. Close cable entry 6. Blue Brown Green/yellow 11.1.2.2 ATEX version (AC version) Solenoid housing Fig. 3: Rear of terminal block Brown Item Name Supply voltage Supply voltage Blue Not connected Green/yellow Earth GEMÜ 0326 14 / 20 www.gemu-group.com...
2. If the plant is new and after repairs blow out the piping system with a fully opened pilot solenoid valve (to remove any harmful foreign matter). Cleaning: • The plant operator is responsible for selecting the cleaning material and performing the procedure. www.gemu-group.com 15 / 20 GEMÜ 0326...
Unlock the manual override as described in "Manual override (optional)" The pilot solenoid valve does not control Medium pressure too low / too high Check medium pressure (see "Technical correctly data") Connections leaking Check the connections (see "Installation") GEMÜ 0326 16 / 20 www.gemu-group.com...
17 Returns 14 Inspection and maintenance goods can be processed only when this note is completed. If no return delivery note is included with the product, GEMÜ WARNING cannot process credits or repair work but will dispose of the goods at the operator's expense.
EU Declaration of Conformity in accordance with 2014/30/EU (EMC Directive) and 2014/35/EU (Low Voltage Directive) GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG Fritz-Müller-Straße 6-8 74653 Ingelfingen-Criesbach, Germany declare that the product listed below complies with the directives named above.
19 EU Declaration of conformity in accordance with 2014/34/EU (ATEX) EU Declaration of Conformity in accordance with 2014/34/EU (ATEX) GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG Fritz-Müller-Straße 6-8 74653 Ingelfingen-Criesbach, Germany declare that the product listed below complies with the requirements of directive 2014/34/EU for intended use in potentially ex- plosive areas.