Selecting The Heating Temperature Set - Biasi RINNOVA CV Series User Manual And Installation Instructions

Table of Contents

Advertisement

(low temperature). Please see also "Selecting
the heating temperature setpoint". For specific
heating system needs, once the climatic curve
has been set, the maximum temperature can
be lowered.
• Enter "programming mode" by carrying out
the procedures indicated in "Accessing the
"programming mode"" on page 37.
17
11
12
Figure 5.51
Figure 5.52
• Press 11 and hold until the LCD display
shows the code A52, indicating entry into
"parameter A52" (Figure 5.53).
Figure 5.53
• By using buttons 14 or 15 (Figure 5.51) it
is possible to modify the value of parameter
A52:
80°C ÷ 50°C = high temperature
55°C ÷ 27°C = low temperature
- 44 -
INSTALLATION
16
15
14
RESET
bar
RESET
bar
• Press 11 or 12 (Figure 5.51) to confirm the
value entered and return to the list of param-
eters (Figure 5.53).
• Press the 16 button (Figure 5.51) to exit
"programming mode".
5.20 Selecting the heating tempera-
ture set
Depending on the type of high or low tempera-
ture heating system, the temperature setting
range can be set.
In heating mode, the boiler is set for tempera-
tures between 50°C and 80°C. This range can
be changed to a minimum of 28°C and a max-
imum of 55°C.
• Enter "programming mode" by carrying out
the procedures indicated in "Accessing the
"programming mode"" on page 37.
17
11
12
Figure 5.54
• Press 11 and hold until the LCD display
shows the code A02, indicating entry into
"parameter A02" (Figure 5.55).
Figure 5.55
• By using buttons 14 or 15 (Figure 5.54) it
is possible to modify the value of parameter
16
15
14
RESET