Extreme Networks' Recommendations - Extreme Networks BlackDiamond 6804 Troubleshooting Manual

Advanced system diagnostics and troubleshooting guide
Hide thumbs Also See for BlackDiamond 6804:
Table of Contents

Advertisement

Extreme Networks' Recommendations

Extreme Networks strongly recommends that you observe the process shown in Figure 11 and outlined
in the steps that follow when dealing with checksum errors.
Figure 11: Diagnostic Troubleshooting Process
Customer
responsibility
TAC
responsibility
1 Is the checksum error a hard error?
The first occurrence of a checksum error doesn't determine whether the error is a hard error or a soft
error. If the error is persistent (doesn't disappear after a reboot) and is accompanied by continuous
and consistent checksum error messages in the system log, it might be a temporary hard error.
If any hardware has been changed recently, and this switch is a modular chassis, try reseating the
affected blade.
Advanced System Diagnostics and Troubleshooting Guide
Customer experiences
checksum errors on
Inferno/Triumph
products.
No
Are these
hard errors?
Yes
Is
Extremeware
No
Software version
6.2.2 or higher?
Yes
Run extended diags/
packet memory scan.
Are
errors detected by
Yes
packet memory scan/
extended diags?
No
Call TAC. Next action
will be determined on the
error frequency and
problem details.
Monitor closely.
No action
needed.
Upgrade to latest EW
and use the packet
memory scan software
to detect and remap
the errors.
Yes
Are
errors recoverable?
No
Call TAC. Product
needs to be replaced.
TAC creates RMA.
Extreme Networks' Recommendations
Errors will be
mapped out. No further
action needed.
Product
replaced.
CG_003
99