Data Network A, Nodes 1 - 22 Cabling Example; Data Networks A And B Cabling Example; Data A, Nodes 1 - 22 Cabling - Dell EMC VxFlex Ready Node Installation Manual

Hide thumbs Also See for EMC VxFlex Ready Node:
Table of Contents

Advertisement

Install Data Network I/O Cables

Data network A, nodes 1 - 22 cabling example

Use the following figure and table to connect cables for the data network A, nodes 1 - 22. The node ports referred to in
this table are 10 G ports.
Note:
In this example, data switch ports have been intentionally left empty. These empty ports can be used for
other user-allocated purposes. If no other use is required for the empty ports, nodes may be connected to the data
switches without leaving empty ports. However, ensure that on each node, each NIC is connected to a different
data switch (either Data Switch A or Data Switch B), in order to prevent a single point of failure in case a switch
fails.
Figure 22 Data networks A and B cabling example
Data Switch B
4
Data Switch A
2
Table 12 Data A, nodes 1 - 22 cabling
Source
Node 1 Onboard Port 0
Node 2 Onboard Port 0
Node 3 Onboard Port 0
Node 4 Onboard Port 0
Dell EMC VxFlex Ready Node Server Installation Guide
50
27
25
Mgmt Server
1
0
Node 16
2
Node 1
0
core switch
48
core switch
48
Destination
Data Switch A Port 2
Data Switch A Port 6
Data Switch A Port 10
Data Switch A Port 14
40 G link to
40 G link to
core switch
40 G link to
40 G link to
core switch

Advertisement