R840 Equipment Installation

R840 server installation guidelines

Minimum and maximum stack up configurations are provided in this topic.
Throughout this document, it is assumed that a 40 U rack is being used. If you plan to use a custom rack, or only part of
a rack, it is highly recommended that a complete analysis is performed in order to ensure that there is enough power
supplied to the nodes. In addition, it is essential that a custom rack has sufficient air flow and heat distribution among
nodes. Therefore, for custom rack configurations, perform an air flow analysis and ensure that there is enough spacing
between nodes.
Ensure that there is at least one redundant power zone available for power connections.
To ensure proper performance and avoid throttling, the R840 server requires the appropriate inlet temperature. Review
this requirement and maintain correct inlet temperature. For more information, see environmental specifications in the
Hardware Replacement and Services Guide .
When systems are installed into an empty rack, always begin component installation at
the bottom of the cabinet and work upward. Install components at the lowest available
space for that component type.
If you are installing the minimum configuration, the stack up will be as follows:
Table 20 Stack up for a minimum configuration
Component Function
Data Server
Management Server
Management Switch
Data Switch
If you are installing the maximum configuration, the stack up will be as follows:
Table 21 Stack up for a maximum configuration
Component Function
Data Server
Management Server
Management Switch
Data Switch
The following illustration represents the maximum R840 configuration.
Dell EMC VxFlex Ready Node Server Installation Guide
82
Description
R840 Server
Management Server
Customer provided 1 GbE
switch
Customer provided 10 GbE
switch
Description
R840 Server
Management Server
Customer provided 1 GbE switch
Customer provided 10 GbE switch 2
Quantity
3
1
1
2
Quantity
Cabinet U Space
13 - 15
3 - 19 and 25 - 39
1
20
1
21
23 - 24
Cabinet U Space
2 - 7
20
21
23 - 24

Advertisement