EverFocus EPTZ1000 User Manual
Hide thumbs Also See for EPTZ1000:

Advertisement

Quick Links

Speed Dome
EPTZ1000
USER MANUAL
th
Date: Aug. 11
, 2005

Advertisement

Table of Contents
loading

Summary of Contents for EverFocus EPTZ1000

  • Page 1 Speed Dome EPTZ1000 USER MANUAL Date: Aug. 11 , 2005...
  • Page 2: Table Of Contents

    1.2.2. EPTZ1000 Base Board... 1-4 1.2.3. EPTZ1000 Control Board ... 1-5 1.3. EPTZ1000 Connection ... 1-6 1.4. EPTZ1000 Quick Operation Guide (Work with EKB500) ... 1-7 EPTZ1000 INSTALLATION ...2-8 2.1. Packing List ... 2-8 2.2. Cable Needed ... 2-8 2.3.
  • Page 3 Embedded ceiling mount ... 2-21 EPTZ1000 CAMERA SETUP MENU...3-22 3.1. Structure of the Setup Menu ... 3-22 3.1.1. Camera Setup Menu ... 3-23 EPTZ1000 FUNCTION SETUP AND OPERATION...4-27 4.1. Manual Control Mode... 4-27 4.2. Auto Pan Mode ... 4-27 4.3.
  • Page 4: Eptz1000 Overview

    1. EPTZ1000 OVERVIEW 1.1. Introduction EPTZ1000, an intelligent high-speed dome camera is ready to secure your property with its omni-directional and exact monitoring. An 18X optical and 12X digital zoom combining with a high-performance chip makes captured images clear and vivid. The other powerful camera functions EPTZ1000 equips with: PAL / NTSC image format suppose.
  • Page 5: Feature

    All of the features make the intelligent high-speed dome camera works for a wide range and demanding application such as banks, airports, stations, casinos, streets of cities, intelligent buildings, and etc. 1.2. Feature 1.2.1. Profile of EPTZ1000 M5 Bolt (Hex) x3 Base PCB board Control board...
  • Page 6: Eptz1000 Control Board

    Video - RS485 + RS485 - AC24 AC24 1.2.3. EPTZ1000 Control Board The PCB board with two dipswitches is the control board of EPTZ1000. The two switches are used to set address, protocol, Baud Rate, video format and terminator resistance.
  • Page 7: Eptz1000 Connection

    1.3. EPTZ1000 Connection 110V AC 24V AC Adapter Video Out RS485 Tx(+) RS485 Tx(-) Alarm 1 Alarm 2 Alarm 3 Alarm 4 GROUND POWER 24V AC / 3.5 A Ω 1.0Vpp ¡ Ó 0.2V, 75 RS485 Control Line EPTZ1000 4 ALARM INPUTS...
  • Page 8: Eptz1000 Quick Operation Guide (Work With Ekb500)

    2. Connect a video cable from EPTZ1000 to a monitor. 3. Connect the power to EPTZ1000 and a keyboard (EKB500). After the EPTZ1000 finishes the self-test mode, you can start to operate the EPTZ1000 via the keyboard. To operate the EPTZ1000:...
  • Page 9: Eptz1000 Installation

    Pin connector x1 M5 screw (Hex) x3 for wall mount bracket fixing M3 screw x3 for bulb fixing 2.2. Cable Needed Power Cable An adapter with 24V AC/3.5A output provides the power to EPTZ1000. An extension power line may be needed.
  • Page 10: Initial Setup

    Note: The input AC voltage range of an adapter depends on different area. Please make sure the voltage range before installing. Video Cable A BNC cable is used for connecting EPTZ1000 to a DVR or a monitor. An amplifier may be needed if the video cable is too long. Control Cable Basically, EPTZ1000 uses a differential pair to connect to other devices by cascading.
  • Page 11: Address Setting

    Note: The factory default address is 1. Notice: Please make sure the power is off before setting, and restart the EPTZ1000 to enable a new value after changing.
  • Page 12 Switch Address Switch Switch Switch Address Address Address Switch Switch Switch Switch 2-11 Address Address Address Address Switch Switch Switch Switch Switch Address Address Address Address Address...
  • Page 13 Switch Address Switch Switch Switch Address Address Address Switch Switch Switch Switch 2-12 Address Address Address Address Switch Switch Switch Switch Switch Address Address Address Address Address...
  • Page 14: Communication Protocol Setting

    PAL / NTSC Maching Resistance Notice: Please make sure the power is off before setting, and restart the EPTZ1000 to enable a new value after changing. Set all of protocol switches to ON; the speed EPTZ1000 will enter a self-test mode.
  • Page 15: Video Format Setting

    Baud Rate PAL / NTSC Maching Resistance Notice: Please make sure the power is off before setting, and restart the EPTZ1000 to enable a new value after changing. 2.3.5. RS-485 Bus Terminator Resistance For central controlling, the terminator resistance should be set for the device that is the furthest one away from the controller.
  • Page 16 Note: When the dome is out of control, or does not work under control well, try to switch the terminator resistance ON. Notice: Please make sure the power is off before setting, and restart the EPTZ1000 to enable a new value after changing.
  • Page 17: Rack And Speed Dome Installation

    2. Check for all necessary materials, and ensure if the selected installation location is suitable for the EPTZ1000. 2.4.2. EPTZ1000 Dome Camera Wall Mount Installation Notice: Installation location that is a wall, pole or a ceiling need to support above five times the total weight of the camera assembly (dome camera and bracket) to avoid shaken images, and dropping.
  • Page 18 4. Connect the cable connectors to the nodes on the PCB board, and then fix the PCB board in the housing by screwing 4 bolts on it. Notice: Please notice the polarity of control line. The EPTZ1000 will not work if the polarity of control line is mis-connected.
  • Page 19 5. Align the two screw holes on the bottom of mechanical part to the two bolts on the base of the housing, and twist the mechanical part clockwise a little bit in order to engage it with the base. Screw the two bolts on the base, and then connect and fix the connection bus to the PCB board on the mechanical part.
  • Page 20: Separately Sold Brackets

    7. Turn on the power, and start to operate the EPTZ1000. When turning on the power, EPTZ1000 will enter self-inspection mode, and carry out a self-testing program. After finishing self-inspection, you can start to operate the EPTZ1000.
  • Page 21: Corner Mount

    2.5.3. Corner mount The corner mounts are used for installing a wall mount bracket to a corner of walls indoors or outdoors. There are two kinds of corner mounts which are 90° and 270° mounts available. 2.5.4. Pole mount The pole mount is used for installing a speed dome on the ceiling indoors or outdoors. The extension poles are available for the pole mount.
  • Page 22: Ceiling Mount

    2.5.5. Ceiling mount 2.5.6. Embedded ceiling mount The ceiling mount is used for installing a speed dome on the ceiling indoor. The embedded ceiling mount is used for lodging a speed dome in the ceiling indoor. 2-21...
  • Page 23: Eptz1000 Camera Setup Menu

    3. EPTZ1000 CAMERA SETUP MENU In this section, setup and operation guide of EPTZ1000 will be introduced. There are 22 items of the setting menu. However, there is only one line on the line display, so using some combination keys to operate is necessary.
  • Page 24: Camera Setup Menu

    3.1.1. Camera Setup Menu Press MENU to enter camera setup menu. Shift Joystick up/down to change subentries, and right/left to change the setting. The name assigned to the camera. 1. CAM ID Digital zoom enable or disable. 2. DZOOM ON: Enable a digital zoom. OFF: Disable a digital zoom.
  • Page 25 Day/Night Mode auto switch. The speed dome will auto switch to night mode, and 7. ICR display in B&W (Black and White) mode to increase the resolution when the illumination is low. ON: Enable the ICR function. OFF: Disable the ICR function. Color display.
  • Page 26 MAN: Manual white balance mode. 13. TITLE DISPLAY : Display the title. ON: Enable title display. OFF: Disable title display. Flip the camera when it tilts to the 90° end. 14. AUTO FLIP ON: Enable auto flip. OFF: Disable auto flip. The status of input alarm 1.
  • Page 27 N.O.: Enable a normal open alarm input. N.C.: Enable a normal close alarm input. OFF: Disable alarm input. The priority of alarms. 19. ALM-IN PRIO 1234: The alarm priority is 1>2>3>4. 2341: The alarm priority is 2>3>4>1. 3412: The alarm priority is 3>4>1>2. 4123: The alarm priority is 4>1>2>3.
  • Page 28: Eptz1000 Function Setup And Operation

    4. EPTZ1000 FUNCTION SETUP AND OPERATION 4.1. Manual Control Mode Manual control: Shift Joystick Up/Down/Left/Right, and turn it Clockwise/Counterclockwise to control speed dome. Use the control keys which are Zoom, Focus and IRIS function keys on the keyboard to zoom In/Out, focus N (near)/F (Far), or IRIS +/-.
  • Page 29: Tour Mode

    then press Shift + Position. The system will ask you to enter the preset position number (1~239), and then press Enter to save the position. There are up to 192 positions can be preset. Set the parameter of a preset position: Press Set + Position to set the parameter of a preset position.
  • Page 30: Alarm To Position/Tour Link

    The camera runs 1→2→3→1→2→3 in the One-way tour mode, and 1→2→3→2→1 in the To-and-fro tour mode. 4.5. Alarm to Position/Tour Link EPTZ1000 have 4 alarm inputs that can be set to link to a position or a tour when an alarm is triggered. Set an alarm link: Press F1 to set an alarm link.
  • Page 31: Appendix A: The Alarm I/O Connection

    APPENDIX A: The Alarm I/O Connection There are 4 alarm inputs and 1 alarm output available. The alarm I/O connector that is marked as JP5 is a nine-pin connector. It is located on the PCB board of the housing. RELAY Video + Video - RS485 +...
  • Page 32 EverFocus Electronics Corp. Head Office: 12F, No.79 Sec. 1 Shin-Tai Wu Road, Hsi-Chih, Taipei, Taiwan TEL: +886-2-26982334 FAX: +886-2-26982380 www.everfocus.com.tw USA Office: 1801 Highland Ave. Unit A Duarte, CA 91010, U.S.A. TEL: +1-626-844-8888 FAX: +1-626-844-8838 www.everfocus.com European Office: Albert-Einstein-Strasse 1...

Table of Contents