Error Message
EDM ERROR
04 -05, 34-39, 50-53
ETH ERROR 70-76
MEMORY ERROR 19
ERROR PS DATA of EDM
ERROR P DATA of EDM
ERROR ETH DATA
System unready
Please restart
13.2 Atmospheric correction
The speed at which light travels through the air varies depending on the temperature and
atmospheric pressure. The R-2500DN is designed to measure distances at the speed of light in
order to measure accurately, atmospheric correction needs to be used. The instrument is
designed to correct for weather conditions automatically if the temperature and pressure are
input. Correction is then carried out based on the following formula.
Calculation formula
K= (276.26713 ‒ 273.14941 + t )
K: Atmospheric Correction Constant
P: Atmospheric pressure (hPa)
t: Temperature(°C)
Distance after Atmospheric Correction D = Ds (1+K)
Ds:Measured distance when no Atmospheric Correction is used.
13.3 hPa and mmHg conversion table
[Converting from hPa to mmHg]
hPa
0
10
500
375
383
600
450
458
700
525
533
800
600
608
900
675
683
1000
750
758
1100
825
833
1200
900
908
88
Meaning
Distance measurement
system problem
Angle measurement system problem
Memory problem
Problem of the internal EDM
parameters
Problem of the internal ETH
parameters
Problem of when activating the
camera
78.565271・P
10
X
273.14941 + t
20
30
390
398
405
465
473
480
540
548
555
615
623
630
690
698
705
765
773
780
840
848
855
915
923
930
-4
40
50
60
413
420
488
495
563
570
638
645
713
720
788
795
863
870
938
945
What to do
Turn the power off,
and then turn on
again
Repair is needed
when the message
appears
consistently.
Unit:mmHg
70
80
90
428
435
443
503
510
518
578
585
593
653
660
668
728
735
743
803
810
818
878
885
893
953
960
968