6. Install the two mounting screws D, washers E, and
locknuts F securing the battery tray stop bracket G
to the frame H.
7. Connect the controller to the controller connector A on
the battery at the rear of the wheelchair.
8. Install the rear shroud and front shroud. Refer to 9.6
Removing/Installing the Shrouds, page 70.
9. If Installing NEW batteries—The Battery Synchronization
Procedure MUST be performed within 24 hours of
powering on the wheelchair. Otherwise the battery
gauge will not display accurate battery charge levels.
The Battery Synchronization Procedure can be found in
the LiNX service manual and must be performed by a
provider or qualified technician.
60101877-B
Fig. 7-9

7.2.14 Replacing Batteries and/or Battery Cables

Have the following tools available: 7/16 inch (6 pt)
Box Wrench and Diagonal Cutters.
Fig. 7-10
Controls System
Fig. 7-11
53