3-2. Automatic Adjustment

To execute the automatic adjustment
1. MSU menu operation:
. MAINTENANCE button→ ON (lit)
. Touch panel operation
[Auto|Setup] → [Auto|Level]
n
When performing automatic adjustment using the menu of the camera, set the setup menu as follows.
MENU: MAINTENANCE
PAGE: AUTO SETUP
ITEM: AUTO LEVEL
2. When the adjustment is completed, a message "Completed" appears.

3-3. Electrical Alignment

3-3-1. BLACK SET Adjustment

Preparation
. Setting for MSU-900
CLOSE button → ON (lit)
MASTER GAIN → 12
Adjustment Procedure
1. Adjustment Item:
MENU: SERVICE
PAGE: BLACK SHADING
ITEM:
BLK SET [R], [G], [B]
2. Adjust this using the waveform monitor so that the PED level of each channel becomes equal within a range of _3 to
+12 dB.
3. Execute STORE FILE.
MENU: SERVICE
PAGE:
BLACK SHADING
ITEM:
STORE FILE
4. Set the value to the value adjusted in step 2 and execute STORE FILE for each format.
(For the format change procedure, refer to the Operation Manual.)