Cares After Using At Special Environment; Error Message In Automatic Adjustment Mode - Sony BVP-950P Maintenance Manual

Color video camera powerhad 1000
Hide thumbs Also See for BVP-950P:
Table of Contents

Advertisement

2-3. Cares after Using at Special Environment

It is recommended to check the following items after using the camera at seaside, dust area or spa.
1. Clean off sand and other dust in the unit carefully.
2. Do not allow salt in seawater or sulfur in spa to contact a not-painted surface of the cabinet. They
may cause to corrode. Clean with alcohol immediately if contacted.
3. Clean the connection surface of connectors.
4. Carry out the common operation check and confirm that the unit normally operates.

2-4. Error Message in Automatic Adjustment Mode

If an error occurs during automatic adjustments, an error message appears on a viewfinder screen. Take
following measures according to the displayed message.
1 "OVER FLOW"
1
1
1
1
The adjusted value overflowed the adjustable range. Check whether the settings on the camera are correct
or not. If they are correct, adjustments of the internal boards are necessary. If adjustments of the boards
are required, contact your local Sony Sales Office/Service Center.
2 "LOW LEVEL"
2
2
2
2
The video signal level was too low for white balance or skin detail phase adjustment, and the white
balance or skin detail phase could not be adjusted. Raise the video signal level by using brighter illumi-
nation, opening the lens iris, or raising the gain of the video signal.
3
3 "TIME LIMIT"
3
3
3
Automatic adjustment did not finish within a specified period. Check whether the settings on the camera
are correct or not. If they are correct, adjustments of the internal boards are necessary. If adjustments of
the boards are required, contact your local Sony Sales Office/Service Center.
4
4 "NOT CLOSE"
4
4
4
The lens did not close for black balance or black shading adjustment.
5
5
5
5 "LOW SATURATION"
5
The saturation of subject was too low for skin detail phase adjustment, and color tone could not be
discriminated. Raise the video signal level by using brighter illumination, opening the lens iris, or raising
the gain of the video signal.
6
6
6
6 "OVER LEVEL"
6
The video signal level was too high for white balance or white shading adjustment, and the color tone
could not be discriminated. Lower the video signal level by using brighter illumination, closing the lens
iris, or to lower the gain of the video signal.
Other message
. . . . .
"BREAK"
The automatic adjustment was interrupted with the BREAK command.
BVP-950 P1
2-3. Cares after Using at Special Environment
2-4. Error Message in Automatic Adjustment Mode