7 . 1 External Cleaning
Clean external surfaces of the laminator with a soft cloth moistened with a mild solution of
detergent (such as dishwashing liquid) and water. Do not use chemical cleaners or solvents, as
these may have a harmful effect on the surface.
7.2 Rollers
Excess adhesive should be removed from rollers periodically. The use of the GBC Silicone
Roller Cleaning Kit is recommended (p/n 1 7 1 1 5 1 5). To gain access to the front rollers it is
necessary to move the heat shoes out of the way. The upper heat shoe will pivot upward. Loosen
the thumb screws on the left and right sides to lower the bottom heat shoe.
7 .3 Heat Shoes
The heat shoes are Teflon coated and can be cleaned with a soft cloth. Abrasive cleaners should
not be used to clean the heat shoes.
7.4 Inspection.
Whenever the cover has been removed for cleaning or corrective maintenance, assure that the
gears are properly lubricated, aligned and secured to their respective shafts. Inspect roller
bearings for wear. Inspect for defects such as loose screws, abraded wires or wire insulation and
loose connections. Correct any defects before returning the laminator to service.
7.5 Lubrication
The motor, idler and roller gears should be lubricated with a heat resistant light silicone
lubricant.