Standard Flush Door; Manual Control Switch Installation - Regency FireGenie PG36D Owners & Installation

Table of Contents

Advertisement

INSTALLATION
02-51
Do not block the burner holes in this
area adjacent to the Log 02-54
11) Test fi re to ensure proper light off (make
sure fl ame fl ows smoothly from one end of
burner to the other). If there is any fl ame
hesitation, check that area for any blockage
of the burner ports.
12) Install fl ush glass and bay glass (if used)
as per instructions in this manual.
STANDARD FLUSH
DOOR
The standard fl ush door comes with a black
frame. To install the frame, simply hook the top
door fl ange onto the top of the unit and swing
the door towards the unit, diagram 1.
Diagram 1
24
02-54
02-50
Be careful that the glass gasket does not roll up;
there must be a gap between the gasket and
the door lip to ensure that the door sits securely
on the unit. Diagram 2.
Use the hook to pull the spring out until you
can put the hook into the slot on the bottom
door bracket. Repeat for 2nd spring.
diagram 3.
To remove the fl ush door, reverse the above
steps.
02-75
02-55
Diagram 2
See
Diagram 3
02-54
02-51
MANUAL CONTROL
SWITCH INSTALLATION
1) Open bottom louver.
2) Mount clip on louver - adjust accordingly
(by sliding) with mounting hole from manual
control box.
3) Secure manual control box (located in the
base of the fi rebox) to the louver using 3
screws.
4) Tuck wires away and close bottom louver.
®
Regency
PG36D Gas Log Fireplace

Advertisement

Table of Contents
loading

Table of Contents