12. Cleaning Convection Blower - Requires No
Lubrication
Frequency: Yearly or more frequently depending on
Dust/Dirt build-up
By: Homeowner or Qualified Service Technician
a. Be sure the appliance is allowed to cool and has
been unplugged.
b. Follow section on Side Curtain Replacement on
page 24
for direct access to the convection blower.
c. Sweep or vacuum out any build-up. Use a brush or
compressed air to loosen dirt if needed.
13. Cleaning the Top Vent Adapter
Frequency: Yearly or more frequently depending on
ash build-up
By: Homeowner
a. The appliance must be in complete shutdown
and the exhaust blower should be off. Allow the
appliance to completely cool down.
b. Open the clean-out cover (Figure 19.1).
c. Sweep or vacuum out any ash build-up.
Clean-Out
Cover
Figure 19.1
19
14. Preparing Firebox for Non-Burn Season
Frequency: Yearly
By: Homeowner
a. Be sure the appliance is allowed to cool, has been
unplugged and the exhaust blower is off.
b. Remove all ash from the firebox and
vacuum thoroughly.
c. Paint all exposed steel, including cast-iron.
— Purchase paint from your local dealer.
— Must use a high-temperature paint made
specifically for heating appliances.