General Information
NOTE: Reference numbers and letters in parentheses
in the text refer to the callouts in the figures and the
parts drawing.
NOTE: Always use Genuine Graco Parts and Acces-
sories, available from your Graco distributor. If you
supply your own accessories, be sure they are ade-
quately sized and pressure-rated for your system.
Fig. 1 is only a guide for selecting and installing sys-
tem components and accessories. Contact your Graco
distributor for assistance in designing a system to suit
your particular needs.
Prepare the Operator
All persons who operate the equipment must be
trained in the safe, efficient operation of all system
components as well as the proper handling of all fluids.
All operators must thoroughly read all instruction
manuals, tags, and labels before operating the equip-
ment.
The following manuals are included with this equip-
ment:
311001 AA Series Spray Gun or 309639 FTx II Spray
Gun
3A0149 AA Series Spray Gun
308995 Falcon and Falcon II Air Motors
308996 Falcon and Falcon II Pumps
6
308994

Installation

Prepare the Site
NOTE: The compressed air supply to the gun must be
clean and dry, to prevent damage to the finish. Use a
coalescing air filter in the main air supply line.
Fig. 1. Ensure that the wall is strong enough to support
the weight of the pump and accessories, fluid, hoses,
and stress caused during pump operation.
Ensure that you have an adequate compressed air
supply.
Bring a compressed air supply line from the air com-
pressor to the pump location. Be sure all air hoses are
properly sized and pressure-rated for your system.
Use only electrically conductive hoses. The air hose
(A) should have a 3/8 npt(m) thread. A quick discon-
nect coupling is recommended.
Install a bleed-type shutoff valve (B) in the air line to
isolate the air line components for servicing. Install an
air line filter (C) and a moisture trap and drain valve
(D) to help remove moisture and contaminants from
the compressed air supply.
Keep the site clear of any obstacles or debris that
could interfere with the operator's movement.
Have a grounded, metal pail available for use when
flushing the system.