Fisher FSOI-180B Operating And Installation Instruction Manual

Dc inverter ducted air conditioning unit

Advertisement

Quick Links

Operating and Installation Instructions Manual
DC Inverter Ducted Air Conditioning Unit
Unit Model:
Thanks for your selection of
instruction manual carefully and keep it properly
(2.6-16kW)
indoor unit
FSLI-180B
FSLI-240B
FSLI-450B-H
FSLI-600B-H
FIHSER
Ducted Air Conditi
-
outdoor unit
FSOI-180B
FSOI-240B
FSOI-450B-3F
FSOI-600B-3F
-
.
oning Unit Before use please read this
to ensure correct use of this machine
-3F
,
.

Advertisement

Table of Contents
loading

Summary of Contents for Fisher FSOI-180B

  • Page 1 Operating and Installation Instructions Manual DC Inverter Ducted Air Conditioning Unit (2.6-16kW) Unit Model: indoor unit outdoor unit FSOI-180B FSLI-180B FSOI-240B FSLI-240B FSOI-450B-3F FSLI-450B-H FSOI-600B-3F FSLI-600B-H FIHSER Thanks for your selection of Ducted Air Conditi oning Unit Before use please read this...
  • Page 2: Table Of Contents

    Safety Considerations Wire controller standard fitting Turning On Off Unit Component Fan Control Description T emperature Setting Sleep Function Setting Operating Mode Setting Fresh Air Valve Setting Timing Setting Operating Operating Energy Saving Setting Instructions Instructions for Line Display of Outdoor Ambient Temperature Controller Power fail Memory Function Setting Debug Function...
  • Page 3: Safety Considerations

    Safety Considerations Please read this manual carefully before use and operate correctly as instructed in the manual. Y ou are specially warned to note the two symbols below A symbol indicating that improper operation might cause human death or severe injury. W ARNING A symbol indicating that improper operation might cause human property damage.
  • Page 4: Wire Controller (Standard Fitting)

    Wire controller (standard fitting) Composition of wire controller Failure status display 1 Timing display Fan speed display (Auto, High speed, Medium Sleep st atus display speed, Low speed) Mode key Defros ting st atus display Se t temperature increase key Energy saving st atus display Se t temperature decr ease key Se t temperature display...
  • Page 5: Turning On Off Unit

    Operating istructions of wire controller Turning ON/OFF unit Pr ess t he ON/OFF ke y, then the unit shall star t up. Pr ess t he ON/OFF key again, then the unit shall shut off. R Fan control (the figures show the relevant display areas) If the fan control key is prssed consecutively, the fan speed shall changes as per t he following sequence: Low speed...
  • Page 6: Sleep Function Setting

    Sleep function setting When the controller functions under cooling or dehumidifying mode and if the unit runs for one hour after the sleep key is pressed, the set tem- perature shall increase by 1, and the set temperature shall increase by another 1 after 2 hours and the unit shall run as per the increased set temperature.
  • Page 7: Fresh Air Valve Setting

    Fresh Air Valve Setting When the unit is shut off, you can enter the fresh air setting by pressing and holding the “FAN” key for 5 consecutive seconds. Now the word “FRESH” flashes on the LCD and the set temperature area shall display the current fresh air setting.
  • Page 8: Timing Setting

    Timer Setting When the unit is shut off, timing start can be set; After the unit is started up, timing shutoff can be set. After the "TIMER"key is pressed, the unit enters the timing set status and the word "TIMER" flashes on the display.
  • Page 9: Display Of Outdoor Ambient Temperature

    Display of Outdoor Ambient Temperature R Under normal conditions, the “OUT ENV” column shall only display the indoor temperature. Press the “SLEEP” key for 5 consecutive seconds when the unit is shut off or start up, the LCD shall display R...
  • Page 10: Failure Display

    Failure Display When there is failure in the unit operation, “ERROR” will flash on the LCD of the wire controller and the code of fai- lure will also be displayed. When there are multiple failures at the same time, the codes of failures will be displayed one after one on the wire controller.
  • Page 11 Definition of Malfunction Codes of DC Inverter General Outdoor Unit V1.6 Outdoor unit Outdoor unit display of LED indicators Indoor Malfunction Item display of dual Unit LED6 LED5 LED4 LED3 LED2 LED1 8 numeral tube Display DC busbar overvoltage protection Bright Blink Bright...
  • Page 12 None AC current protection (input side) Bright Blink Bright Blink Bright Dark Driver board environment temperature Bright Blink Bright Blink Dark Bright sensor malfunction AC input voltage abnormality * Electrification loop malfunction * Note: 1、 No indicator LED6 for FSOI-180B.
  • Page 13: Operation Of Remote Controller

    Operation of Remote Controller Precautions: • Ensure there is no obstacle between the remote controller and the signal recei- ving window of the air conditioner. • The distance able to receive the signal of the remote controller can be as far as 8 meters.
  • Page 14 Cooling Mode Operation Connect the unit to power supply. Press the “ON/OFF”key. Press the “MODE” key to select “Cooling” mode. Use the “Temperature” key to adjust the set temperature for the room. a) After the unit is connected to power supply, the air conditioning unit shall enter the operating status if you press the ON/OFF key b) Press the mode key and select the...
  • Page 15 DRY (Dehumidifying) Mode Operations Connect the unit to power supply. Press the “ON/OFF” key. Press the “MODE” key to select “DRY (Dehumidifying)” mode. Use the “Temperature” key to adjust the set tempe- rature for the room. a) After the unit is connected to power supply, the air conditioning unit shall enter the operating status if you press the ON/OFF key...
  • Page 16 Loading Batteries Into Remote Controller • After batteries are installed, the display shall display icons and letter codes of all functions. • The life of batteries is about 1 year. • Do not mix new and old batteries or mix different types of batteries in usage •...
  • Page 17: Unit Function

    U nit Function • 7DP - Seven days programmer (Accessory not supplied) Centralized Control and Week Timer trol and the week timing functions. the lower unit. The weekly timing fun- Functions: The centralized control- Up to 16 sets of units can be control- ction is able to realized four timing ler and the weekly timer are integra- led simultaneously by the centralized...
  • Page 18 Note: 1. For upper unit checks 16 lower units consecutively, there will be no more than 16 seconds delay when setting works till unit responds. Please let us know your requirement before your placing the order, for this WEEKLY TIMER will only be prepared when customer orders (communication joint with WEEKLY TIMER on manual control had been prepared).
  • Page 19: Wire Controller (With Week Timer Functions)

    Wire controller (with week timer functions) Composition of wire controller(Accessory not supplied) Sleep st atus display 1 Timing display Mode key Fan speed display (Auto, High speed, Medium speed, Low speed) Se t temperature incr ease key Defros ting st atus display Se t temperature decr ease key Energy saving st atus display Fan speed key (fresh air setting)
  • Page 20 • Wire controller with week timer function,No.1-No17 is the same as front   • instructions of No18,No.19: Timer setting (Fig. 15, 16, 17)   The timer function of this display board is invalid when connect with the timer   SEG of the last week, the display board will be controlled by the week timer.
  • Page 21 If enter into timer setting, by pressing “Mode” button to select the setting item: Day (Monday to Sunday), Segment (1-4), Timer (timer on or timer off), the ON Minutes and Hours of the time; By DAY              SEG pressing “▲”、“▼” buttons to adjust the setting, then press the Timer button to confirm, and press the Timer button once more to cancel the setting;...
  • Page 22 If enter into “Cancel Timer”, by pressing   “▲”、“ ” buttons to select Week, then   press the “Timer” button to confirm, at this   time, “dd” will display; or press “Timer” DAY   button to cancel the selected day, at this  ...
  • Page 23: Dual Sensor Setting

    Unit Function Setting of Indoor Room Sensor and Checking of Outdoor Ambient Temperature 1. Setting of Double Indoor Room Sensors This series of ducted air-conditioning unit has two indoor room sensors. One is located at the air intake of the indoor unit and the other one is located inside the wire controller. User can select one from the two indoor room sensors on the basis of the engineering requirement.
  • Page 24 Unit Function Fresh Air Control Pump Air Control Pump 3. Fr 3. Fresh Air Control 11-levels control can be realized for the amount of fresh air taken in. The function not only facilitates the health of users but also controls the electricity consumption loss because of taking in fresh air. This kind of control can be carried out through the wire controller.
  • Page 25: Installation Dimension Of Indoor Unit

    Instructions of Unit Installation Profile Dimensions of Indoor Unit Profile Dimensions of Indoor Unit E le c tric B o x L iq u id P ip e G a s P ip e A ir In ta ke D ra in a g e P ip e A ir In ta k e Be suit for : FSLI-180B...
  • Page 26 Ins truc tions of Unit Ins tallation P rofile Dimens ions of Indoor Unit P rofile Dimens ions of Indoor Unit Item Model FSLI-180B × 932 430 738 894 1012 736 738 125 207 266 1/4" 1/2" 30 1.5 × 1.2...
  • Page 27: Installation Of Outdoor Unit

    Instructions of Unit Installation Profile Dimensions of Outdoor Unit 1. Profile Dimensions of Outdoor Unit Unit:mm Fig. 30 Model FSOI-450B-3F FSOI-600B-3F FSOI-180B FSOI-240B Item 1032 1250 F ig. Unit Ins tallation Ins truc tions P rec autions on Ins tallation of Outdoor Unit...
  • Page 28 Unit Installation Instructions Installation of Indoor Unit (4) Avoid direct sunshine over the unit. It is better to set up a sun shield as the protection. (5) Place of installation must be able to drain the rainwater and defrosting water. (6) Place of installation must ensure the machine will not be buried under snow or subject to the influence of rubbish or oil fog.
  • Page 29: Indoor Unit Level Inspection And Air Duct Installation

    Unit Installation Instructions Inspection of Level of Indoor Unit, Fabrication of Backwater Elbow Precautions for unfavorable installation: 1. The preparation of all pipes (connecting pipes and drainage pipes) and cables (connecting lines of wire controller, indoor unit and outdoor unit) must be ready before the installation, so as to achieve smooth installation.
  • Page 30: Pipe

    Unit Installation Instructions Installation of Drainage Pipeline Cautions: The air supply pipe, the air intake pipe and the fresh air pipe must be covered with a layer of thermal insulation, so as to avoid thermal leakage and condensation. Firstly apply liquid nail on the pipes, then attach the thermal insulation cotton with a layer of tinfoil.
  • Page 31 Unit Installation Instructions Inst allation of Condensate Pipe Testing of Drainage System (1) After the electrical installation is completed, carry out the testing of the drainage system During the test check if the water correct ly flows through the pipelines Carefully observe the joints to ensure that there is no leakage If the unit is to be installed in a new house carry out testing befo...
  • Page 32: Installation Of Connecting Pipe

    Instructions of Unit Installation Connection of Pipelines Connection of Pipeline 1. Align the flared end of the copper pipe with the center of the thread joint. Manually tighten the flared end nut. 2. Use torque spanner to tighten the flared end nut until the spanner clatters (Figure 38). One-Way Valve Gas Valve Liquid Valve...
  • Page 33 Instructions of Unit Installation Installation of Connecting Pipe 10. If conditions allow, use a vacuum pump to remove air out from the valve. Refer to Figure 40 Pressure Gage Pressure Gage “HI” Knob “LO” Knob Liq id Valve Vacuum Pump Connecting Hose Gas Valve Fig.40...
  • Page 34: Position And Method Of Installing Wire Controller

    Instructions of Unit Installation Installation of Connecting Pipe (2) Use thermal insulation tape to wrap the pipes from the bottom of the outdoor unit until the upper end of the pipe where the pipe enters the wall. When wrapping thermal insulation tape, the later circle of tape must cover half of the front circle of tape (Refer to Figure 42).
  • Page 35 Instructions of Unit Installation Installation of Wire Controller Electric box cover sketch map for indoor unit communication wire Wire clamp Cable-cross loop Control wire Communication wire metallic pipe metallic pipe Figure 43 Surface Figure 44 Concealed Figure 45 Schematic Diagram of Installation Mounting of Cable mounting of Cable Name...
  • Page 36 Instructions of Unit Installation Electrical Installation Caution: Before installing the electrical equipment, please pay attention to the following matters which have been specially pointed out by our designers: (1) Check to see if the power supply used conforms to the rated power supply specified on the nameplate.
  • Page 37 Instructions of Unit Installation Electrical Installation (4 ) Use cable fastener to bundle and fix the cable. 2。 Air-conditioning unit with 3-phase power supply Caution: 1 Remove the front-side panel of the outdoor unit. Take great care when carrying out the following 2 Attach rubber ring to the cable-cross hole of the connections, so as to avoid malfunction of the outdoor unit.
  • Page 38: Connection Of Cables

    The section area of cables selected by users must not be smaller than the specifications shown diagram the signal wire between indoor and outdoor unit shall be installed in the shielded bushing Schematic Diagram of Unit Line Connection: FSOI-240B FSOI-180B × × ×...
  • Page 39 Instructions of Unit Installation Troubleshooting and Maintenance If your air-conditioning unit suffers from abnormal operation or failure, please first check the following points before repair: Failure Possible Reasons The power supply is not connected. Electrical leakage of air-conditioning unit causes tripping of leakage switch. The unit cannot be started.
  • Page 40: Troubleshooting And Maintenance Of Air Conditioner

    Instructions of Unit Installation Troubleshooting and Maintenance 4) Take care when cleaning the air-conditioning unit. Use a steady stepping stand. 2. Maintenance at the Beginning of Operating Season Check the air inlet and outlet of the indoor and outdoor units to confirm there is no blockage. Check to see if the grounding wire is in good condition;(Operating by the professional) Check to see if the line connection is in good condition;(Operating by the professional) Check if there is any word displaying on the LCD of the wire controller after connecting the unit...
  • Page 41: Appendix

    Appendix: Air conditioner nominal working condition and working range: Indoor side Outdoor side Test condition DB(℃) WB(℃) DB(℃) WB(℃) Nominal cooling Nominal heating ―― Rated cooling Low temp. cooling ―― 18 Rated heating ―― Low temp. heating ―― -7 -8 Note: 1.
  • Page 42 This product must not be disposed together with the domestic waste. This product has to be disposed at an authorized place for recycling of electrical and electronic appliances. 66129906999...