Viessmann Vitocal 222-S Installation And Service Instructions For Contractors page 45

Compact heat pump, split version
Table of Contents

Advertisement

Electrical connection
Swimming pool heating
Note
Swimming pool heating is controlled via EA1 exten-
sion with KM-BUS.
Make connections to EA1 extension only in accord-
ance with Fig. 41.
A filter circuit pump cannot be controlled via the heat
pump control unit.
[{A
[{S
DE
DE
1 2
1 2
3 4
K
H
Fig. 41
EA1 extension
A
Power supply 1/N/PE 230 V/50 Hz
B
Junction box (on site)
C
Fuses and contactor for circulation pump for swim-
D
ming pool heating (accessories)
Jumper
E
3-way diverter valve for "swimming pool" (zero
F
volt: Charging the heating water buffer cylinder)
(cont.)
A
[{D
[{{]
DE
0-10V
5 6
+ -
f-]
A
E
N
L1
B
L1 N
C
D
M
1~
F G
Circulation pump for swimming pool heating
G
(accessories)
Temperature controller for regulating swimming
H
pool temperature (floating contact: 230 V~, 0.1 A,
accessories)
KM-BUS connection to the controller and sensor
K
PCB
Installation sequence
45