Viessmann Vitocal 222-S Installation And Service Instructions For Contractors page 151

Compact heat pump, split version
Table of Contents

Advertisement

Specification
(cont.)
Type AWBT/AWBT-E/AWBT-E-AC
Refrigerant line connections
Liquid line
Pipe
7
Indoor unit
Outdoor unit
Hot gas line
Pipe
7
Indoor unit
Outdoor unit
Length of liquid line and hot gas line
Heating mode
Cooling mode
Sound power of outdoor unit at rated heating output
(Measurements with reference to EN 12102/
EN ISO 9614-2)
Weighted total sound power level
3 K
5 K
At A7
±
/W55
±
(max.)
3 K
5 K
At A7
±
/W55
±
in night mode
Energy efficiency class to EU Regulation no.
811/2013
Heating, average climatic conditions
Low temperature applications (W35)
Medium temperature applications (W55)
DHW heating, draw-off profile (L)
Performance data as per EU Regulation
no. 811/2013 (average climatic conditions)
Low temperature applications (W35)
Energy efficiency
η
S
Rated heating output P
rated
Medium temperature applications (W55)
Energy efficiency
η
S
Rated heating output P
rated
Sound power level to ErP
Sound power level, outdoor unit
221.C10
mm
10 x 1
UNF
UNF
mm
16 x 1
UNF
UNF
m
3 to 30
m
3 to 30
dB(A)
61
dB(A)
55
A
A
%
180
kW
9.75
%
132
kW
9.67
dB(A)
56
Specification
221.C13
221.C16
10 x 1
16 x 1
3 to 30
3 to 30
61
55
++
A
++
++
++
A
A
A
183
11.17
131
10.83
56
10 x 1
16 x 1
3 to 30
3 to 30
61
55
A
++
++
A
A
182
134
11.98
56
151