VIVAX
① Construct a large canopy.
② Construct a pedestal.
Install the unit high enough off the
ground to prevent it from being buried
in snow.
INSTALLATION PRECAUTIONS
Dimensions
4/6 kW (unit: mm)
Model
4/6kW
1008
8/10/12/14/16
1118
kW
Fig 6‐1
A
B
C
375
426
456
523
Prevent Sunshine
As the outdoor temperature is
measured via the outdoor unit air
thermistor, make sure to install the
outdoor unit in the shade or a canopy
should be constructed to avoild direct
sunlight, so that it is not influenced by
the sun's heat, otherwise protection
may be possible to the unit.
Uncovered scene, anti‐snow shed
must be installed:
(1) To prevent rain and snow from
hitting the heat exchanger,
resulting in poor heating capacity
of the unit, after long time
accumulation,
exchanger freezes;
(2) To prevent the outdoor unit air
thermistor from being exposed
to the sun ,resulting in failure to
boot;
(3) To prevent freezing rain.
8/10/12/14/16 kW (unit: mm)
D
E
F
663
134
110
656
191
110
14
ENG
WARNING
the
heat
Fig 6‐2
G
H
I
170
712
160
170
865
230