The equipment is not intended for use in a potentially explosive atmosphere.
-
Places where servicing space can be well ensured.
-
Places where the units' piping and wiring lengths come within the allowable
ranges.
-
Places where water leaking from the unit cannot cause damage to the location
(e.g. in case of a blocked drain pipe).
-
Places where rain can be avoided as much as possible.
-
Do not install the unit in places often used as a work space. In case of
construction work (e.g. grinding etc.) where a lot of dust is created, the unit
must be covered.
-
Do not place any object or equipment on top of the unit (top plate)
-
Do not climb, sit or stand on top of the unit.
-
Be sure that sufficient precautions are taken in case of refrigerant leakage
according to relevant local laws and regulations.
-
Don't install the unit near the sea or where there is corrosion gas.
When installing the unit in a place exposed to strong wind, pay special attention to
the following:
-
Strong winds of 5 m/sec or more blowing against the unit's air outlet causes a
short circuit (suction of discharge air), and this may have the following
consequences:
-
Deterioration of the operational capacity.
-
Frequent frost acceleration in heating operation.
-
Disruption of operation due to rise of high pressure.
-
Motor burnout.
-
When a strong wind blows continuously on the front of the unit, the fan can
start rotating very fast until it breaks.