  • Page 1 AD610 ® ShowLink Access Point Print and web guide for AD610 ShowLink Access Point Version: 4.0 (2021-G)
  • Page 2: Table Of Contents

    Shure Incorporated Table of Contents Power Over Ethernet AD610 ShowLink® Access Point External Power Supply (Optional) IMPORTANT SAFETY INSTRUCTIONS Networking AD610 ShowLink Access Point Reset Option Features Positioning the Access Point ShowLink Access Point Overview Network Mode Furnished Accessories Control and Configure the Access Point with Wireless...
  • Page 3: Ad610 Showlink® Access Point

    Shure Incorporated AD610   ® ShowLink Access Point IMPORTANT SAFETY INSTRUCTIONS READ these instructions. KEEP these instructions. HEED all warnings. FOLLOW all instructions. DO NOT use this apparatus near water. CLEAN ONLY with dry cloth. DO NOT block any ventilation openings. Allow sufficient distances for adequate ventilation and install in accordance with the manufacturer’s instructions.
  • Page 4: Ad610 Showlink Access Point

    Shure Incorporated Caution: risk of danger (See note.) Direct current Alternating current On (Supply) Equipment protected throughout by DOUBLE INSULATION or REINFORCED INSULATION Stand-by Equipment should not be disposed of in the normal waste stream WARNING: Voltages in this equipment are hazardous to life. No user­serviceable parts inside. Refer all servicing to qualified service personnel. The safety cer­ tifications do not apply when the operating voltage is changed from the factory setting.
  • Page 5 Shure Incorporated ShowLink Access Point Overview ① ShowLink 2.4 GHz detachable antennas For 2.4 GHz signals ② ShowLink Data Status LED (blue) ◦ ON Steady: Linked, no data transmission ◦ Flashing: Transmitting data. Rate of flashing indicates level of activity ③...
  • Page 6: Furnished Accessories

    Shielded 25 foot Ethernet cable for ShowLink access point, RJ45-to-EtherCon con- 95A15104 nector Power Supply PS43 Note: Model availability depends on region. See your local Shure dealer or distributor for details. Optional Accessories Directional 2.4 GHz patch antenna AXT644 (available depending on regional regulations) ShowLink Basics ShowLink Channels and 2.4 GHz Spectrum...
  • Page 7: Coverage Area

    Power Over Ethernet The Shure Ethernet switch and Axient rack components offer network ports with Power over Ethernet (PoE). The network port powers the access point as long as the host component is powered on. Insert a Cat 5 Ethernet cable into the Ethernet port located on the body of the access point.
  • Page 8: External Power Supply (Optional)

    Shure Incorporated External Power Supply (Optional) If Power over Ethernet (PoE) is not available, power the access point using an external power supply. Connect the power supply to the external power supply jack. Tighten the locking ring to secure the plug.
  • Page 9 Shure Incorporated Positioning the Access Point • Provide a clear line of sight between the access point and devices. Mount the access point on a microphone stand or wall to elevate above obstructions. • Position the antennas vertically for optimal performance. The swivel joint on each antenna allows a wide range of position­ ing to maintain a vertical alignment.
  • Page 10: Network Mode

    Shure Incorporated Wall Mount Network Mode Set a host ID on the AD610 to connect to an ADX5D portable receiver in network mode. An AD610 with a host ID set grants ac­ cess to ADX5Ds with a matching client ID. Update your AD610 to the latest firmware and download the latest version of Wireless Workbench. Connect the access point to your network using a Class 1 Power over Ethernet (PoE) port.
  • Page 11: Setting Power Levels

    Shure Incorporated Tip: The text color of the device ID for each transmitter in the Connected list indicates link quality: • Green = Excellent • Yellow = Good • Red = Marginal Hovering the cursor over the Device ID displays link quality ranked from 5 to 1.
  • Page 12 Shure Incorporated Dimensions 190 mm x 102 mm x 47 mm (7.48 in. x 4 in. x 1.85 in.) H x W x D, without antennas Weight 464 g (16.3 oz.), without antennas Housing Extruded Aluminum Power Requirements Power over Ethernet (PoE) Class 1 36 to 57  V DC/V AC External Power Supply (if PoE is unavailable) 15 V DC (600 mA), double insulated...
  • Page 13: Certifications

    This product meets the Essential Requirements of all relevant European directives and is eligible for CE marking. Hereby, Shure Incorporated declares that the radio equipment is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: http://www.shure.com/europe/compliance...
  • Page 14: Important Product Information

    Important Product Information LICENSING INFORMATION Licensing: A ministerial license to operate this equipment may be required in certain areas. Consult your national authority for possible requirements. Changes or modifications not expressly approved by Shure Incorporated could void your authority to operate the equipment. Licensing of Shure wireless microphone equipment is the user’s responsibility, and licensability de­ pends on the user’s classification and application, and on the selected frequency. Shure strongly urges the user to contact the ...
  • Page 15 Shure Incorporated 万一、この機器から移動体識別用の構内無線局に対して有害な電波干渉の事例が発生した場合には、 速やかに使用周波 数を変更するか又は電波の発射を停止した上、下記連絡先にご連絡頂き、混  信回避のための処置等(例えば、パーティ ションの設置など)についてご相談して下さい。 その他、この機器から移動体識別用の特定小電力無線局あるいはアマチュア無線局に対して有害な電波干渉の事例が発生 した場合など何かお困りのことが起きたときは、保証書に記載の販売代  理店または購入店へお問い合わせください。代 でもご覧いただけます。 理店および販売店情報は Shure 日本語ウェブサイト  http://www.shure.co.jp 現品表示記号について 現品表示記号は、以下のことを表しています。 この無線機器は 2.4GHz 帯の電波を使用し、変調方式は「 DS 」方式、想定与干渉 距離は 40m です。 2,400MHz ~ 2,483.5MHz の全帯域を使用し、移動体識別装置の帯域を回避することはできません 。 15/15...